See All Software See All Aufnehmer See All Elektroakustisch See All Akustische End-of-Line-Testsysteme See All Vibration Testing Equipment See All Systeme und Datenerfassung See All Akademie See All Anwendungen See All Industrien See All Services See All Support See All Sustainability See All Our Business See All Our History See All Careers See All Globale Präsenz
arrow_back_ios

Main Menu

See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Inertial Sensor Software See All Acoustic See All Current / voltage See All Displacement See All Schwingungserreger See All Force See All Inertialsensoren See All Wägezellen See All Pressure See All Smarte Sensoren mit IO-Link-Schnittstelle See All Strain See All Torque See All Vibration See All Testlösungen See All Aktoren See All Verbrennungsmotoren See All Betriebsfestigkeit See All eDrive See All Sensoren für Produktionstests See All Getriebe See All Turbolader See All LDS-Shaker-Systeme See All Leistungsverstärker See All Schwingungsregler See All DAQ Systeme für die mechanische und Struktur-Analyse See All DAQ-Systeme für Sound & Vibration&V See All Industrie-Elektroniken See All Leistungsanalysator See All Handgehaltene Geräte für Schall und Schwingung See All Drahtloses Datenerfassungssystem See All DAQ Systeme für die mechanische und Struktur-Analyse See All Schulungskurse See All Akustik See All Anlagen- und Prozessüberwachung See All Elektrische Energie See All Kundenspezifische Sensoren See All NVH See All Zuverlässigkeit See All Smarte Sensoren See All Schwingbelastung See All Strukturelle Integrität See All Automobil & Bodentransport See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Our People See All Compliance
arrow_back_ios

Main Menu

See All BK Connect / PULSE See All API See All Microphone sets See All Cartridges See All Spezialmikrofone See All Akustische Kalibratoren See All Mikrofon-Vorverstärker See All Schallquellen See All Zubehör für akustische Sensoren See All Accessories See All Leistungsverstärker See All Zubehör für Schwingprüfsysteme See All Accessories See All Bending / beam See All Zubehör für Wägezellen See All DMS für die Experimentelle Spannungsanalyse See All DMS für den Aufnehmerbau (OEM) See All Zubehör für Dehnungsmessstreifen See All Nicht rotierend (Kalibrierung) See All Rotierend See All CCLD (IEPE)-Beschleunigungssensor See All Ladungs-Beschleunigungssensor See All Impulse hammers / impedance heads See All Drehzahlsensoren See All Kabel See All Accessories See All QuantumX See All SomatXR See All MGCplus See All Optische Interrogatoren See All CANHEAD See All LAN-XI See All Fusion-LN See All Zubehör für Industrieelektroniken See All GenHS See All Zubehör für GenHS See All Software für handgehaltene Geräte See All Zubehör für handgehaltene Geräte für Schall und Schwingung See All Drahtlose DAQ Gateways See All Drahtlose DAQ-Knoten See All Elektroakustik See All Schallquellenortung See All Umgebungslärm See All Produkt-Lärm See All Schallleistung und Schalldruck See All Vorbeifahrgeräusche See All Strukturüberwachung See All Produktionsprüfung und Qualitätssicherung See All Maschinenanalyse und -diagnose See All Strukturüberwachung See All Batterieprüfung See All Einführung in die Messung elektrischer Leistung bei transienten Vorgängen See All Transformator-Ersatzschaltbild | HBM See All Strukturelle Dynamik See All Prüfung der Materialeigenschaften See All Sicherstellung der strukturellen Integrität von Leichtbaustrukturen See All Elektrifizierung von Fahrzeugen See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

WHAT IS SIGNAL CONDITIONING

A typical signal conditioning system includes the signal conditioning hardware, which works as an interface between the raw signals and transducer outputs and the measurement device. In turn, a signal conditioning unit supplies functions such as signal amplification, attenuation, electrical isolation, filtering, powering, overload detection and Transducer Electronic Data Sheet (TEDS).

SIGNAL CONDITIONING HARDWARE

When deciding which conditioner to use, you should consider the type of transducer as well as the conditioner's benefits to the measurement system, including the following critical features and characteristics.

Number of Channels: For multi-channel tests, having more channels in the signal conditioner makes for a simpler system (for example, one power supply or battery for all the conditioned channels).

Channel Control: For units with adjustable settings, manual control is the easiest way to change configuration. In automated or multi-channel systems, computer control offers big time savings.

For very large systems, it is desirable to control as many channels as possible from a single PC.

WHY IS SIGNAL CONDITIONING NEEDED?

The signal conditioner's main task is to convert the picked-up signal into a higher-level electric one. The signal from the sensor that is generated might need to be converted to be usable and to suit the different instruments it is connected to. Any standard process signal can be achieved by converting any sensor signal.

Besides needing to cover the measurement's frequency range, the analog filter of a signal conditioner can remove portions of the signal outside the range of interest.

For example, in-vehicle measurements of sound often have very strong low-frequency content below 20 Hz. A 20 Hz high-pass filter will attenuate the signal below the audio range which may improve the measurement system's noise floor at mid to high frequencies.

In addition to adjustable filters, signal conditioning offers gain control and other benefits:

Minimum and Maximum Gain: When using data acquisition system with adjustable input signal ranges, the noise floor of the complete measurement system (from transducer through conditioning to data acquisition) can be improved by adding gain in the conditioner.

Uni (Fine) Gain Adjustment: The sensitivity of a transducer in engineering units or volts typically varies significantly between individual transducers. Compensating for the individual sensitivities using fine gain control in the conditioner removes this error.

Transducer Electronic Data Sheet (TEDS): Significant measurement errors can be automatically avoided when the fine gain adjustment of the conditioner is read from the transducer's built-in TEDS support.

Multi-unit Rack: Assembling a rack for mounting is a convenient way of organising laboratory- based measurement systems where all the conditioning and data acquisition are combined. For most signal conditioners, you can order an optional 19-inch rack and/or a multi-unit frame, with which a single or more conditioner can be mounted together.

Signal Amplification:Increasing the signal (signal amplification) is a two-way process that is needed for digitalization or processing. The signal amplification can be carried out by either increasing the resolution of the input signal or by increasing the signal to noise ratio.

When using the LAN-XI DAQ System, you are provided with Dyn-X technology for unrivalled dynamic headroom.

SIGNAL CONDITIONING FOR ACOUSTIC TRANSDUCERS

For acoustic transducers, signal conditioning adds many benefits, such as:

Polarization Control: The working principle of the condenser microphone is based on a fixed charge. This charge is established, either with a very stable external polarization voltage, typically 200 V, via a large resistor, or by an electret layer deposited on the microphone's backplate, in which case the external polarization voltage should be set to 0 V.

CIC (Charge Injection Calibration): CIC is a technique for on-line verification of the integrity of the entire measurement chain, for example, microphone, preamplifier and cabling. Even microphones remote from the input stage/conditioning amplifier can be verified.

The philosophy behind CIC is that if we have a known condition (for example, a properly calibrated microphone) and establish a reference measurement, then as long as the reference value does not change, nothing has changed, for example, the microphone calibration will still be valid.

Signal Filtering: A-, B-, C-, and D-weighting

A-weighting Filters

Sound measurements often specify A-weighting to reflect the acuity of the human ear, which does not respond equally to all frequencies. Using analog A-weighting filters can also have the same benefit of improving the measurement system's noise floor at mid to high frequencies for in-vehicle measurements.

B‐, C‐, and D‐weighting Filters

To accurately measure sound, one can also specify B‐, C‐ or D‐weighting instead of the more common A‐weighting. These additional weightings also reflect the acuity of the human ear, which does not respond equally to all frequencies, but also has a different response at different sound pressure levels.

AC Velocity and Displacement Output (Single‐ and Double‐ integration Filters)

In some measurements, such as machine health monitoring according to ISO 10816, the velocity or displacement is of more interest than the acceleration from an accelerometer. A single and double integration filter easily converts an acceleration signal to velocity or displacement in the time domain.

Converting to velocity or displacement in the conditioner makes further analysis easier.

DC RMS and Peak Outputs and Alarms

Some analysis techniques use averaged (RMS) or Peak measurements instead of the “raw time” output signal. Conditioners with this capability are often called “measuring amplifiers” because they provide the needed measured parameter without need for additional instrumentation.

Besides being displayed on the unit’s screen, the averaged (RMS) or Peak values can be sent to other measurement devices as a DC voltage. A TTL alarm output can be sent from the measuring amplifier when a limit is exceeded.

WANT TO KNOW MORE?

For further details of the range, availability, and price, please use the link below to get in touch with your local Brüel & Kjær representative.