Microsoft .NET 7.0, previously used in Team Sharing, is now out of support. Therefore, Team Sharing has been upgraded to use .NET 8.0 to ensure continued performance, security, and stability.
The updated Team Sharing installer will automatically install .NET 8.0 on your machine, if it is not already present.
We highly recommend that all Team Sharing users upgrade to the latest version.
Thank you for your attention and continued support.
The Team Server has never been an actual 'server', rather a set of services and tools that utilize a folder, local or shared network, as a file repository for storing files.
There is no database to install or upgrade. No server to write to. The index tools read (never write) files in the repository to create an index on which queries are performed.
To clear up this misconception of an actual server and emphasize the key benefit, we have renamed Team Server to Team Sharing. The name change has been adopted throughout the user interface and in the new editing task, Data task, where you can edit the properties of any BKC file stored in the file repository.
For more information, see the Readme.
Our engineers are always working to improve software functionality, from new features to better software user experience based on real-world needs, constant testing and user feedback. See our latest innovations and updates below.
Added import support of Hdf5 files from Tescia
New web app for Team (File) Sharing
Added reference curve types: CPB and order spectra
Additional LAN switches are available to choose from in the Front-end Setup program (Synch Setup dialog), including PTPv2 switches for improved PTP synchronization.
All import/export file formats available in Data Viewer Type 8400 license are now available in all applets.
New hot keys created for start, stop and reset in the Record and Process task
The displays in the Record and Process task improved with Test-based Viewer functionality
Added display types and display layouts to Test-based Viewer allowing you to quickly define how test results are displayed and compared
Added cancel option with fast and standard displays to stop the display process if your selection includes too many files and signals and thereby takes a long time.
Generator fans shut-off automatically when measurement begins
Hot keys have been added to the most used buttons in the Measurement Control in the Hammer, Shaker and Stepped Sine Setup and Measurement tasks.
A-weighting on sound pressure time signals is now also implemented for frequency spans below 1.6kHz in the Hammer and Shaker Setup and Measurement tasks.
Support for new Array Microphone Type 4957.
BK Connect Indoor Pass-by, Pass-by SPC and Volume Velocity Measurements
Background noise before
Background noise after
Added a 'toggle' button that allows you to show/hide background noise runs in measurement tasks
In order to speed up processing, the Indoor Pass-by Set Up task now contains a slimmed-down version of the Test Plan, with only the most minimal of parameters for proper testing according to the standards
Pass-by Calculations now include tyre noise calculations to enable a better and seamless support of tyre noise corrections
BKCSV-55:Fixed: SIG files can now be imported and exported.
BKCSV-146:Fixed: Import of Hdf5 files from HBK Tescia now supported.
BKCSV-357:Fixed: The time stamp on exported H5 files is now correct.
BKCSV-142:Fixed: Implementation of automatic shut down of generator fans during measurement.
BKCSV-113:Fixed: When recording with a GADI signal, chances of buffer overrun reduces if the sampling rate over Gadi interface increases. See the workaround above.
BKCSV-311:Fixed: Fast display contour plots of frequency vs RPM of a run-down analysis, using the FFT vs RPM element, now renders correctly including corresponding order cursors.
BKCSV-265:Fixed: Edits of markers and regions on recordings persist after reloading the recordings.
BKCSV-267:Fixed: The order of time regions in the Project Browser no longer changes when reloading a project.
Modal Analysis BKCCRM-971:Fixed: Fixed persistence of selection of FRFs as MIF in Parameter Estimation and Mode Selection tasks. Deselection of FRFs in the function table gives the default display of the Driving Point FRFs.
Structural Measurements BKCSV-404:Fixed: Live trigger display in Hammer Trigger setup again functions as intended.
Geometry BKCSV-371:Enhancement: Significantly decreased the time to delete nodes and elements in large geometries and added undo/redo deletion functions to the GUI in the process.
BKCSV-426:Fixed: The calculation mesh size is maintained when the range is moved.
Added CAN-FD support to the existing CANcard/CANbox solution in Labshop (CANLogger)
Added support for CAN signals and CAN-FD signals from vector
The Transducer Database has been updated with additional HBK-branded Dytran transducers
Additional LAN switches are available to choose from in the Front-end Setup program (Synch Setup dialog), including PTPv2 switches for improved PTP synchronization.
Added support for R51 Revision 03 Amendment 10
Added support for R117-04 Series Supplement 2
Added support for ISO/DIS 16254:2023
Implementation of UN Regulation 138 Rev. 2 extended:
Max Hold Spectrum is displayed for bothe sides in stead of the lower one.
A pair of microphones, instead of groups (2 × 5) of microphones, is enough to run the measurement.
It is possible to work without engine speed signal in Standard mode.
In addition to the standard forward 10k, forward 20k, reverse 6k, and reverse standstill, it is possible to add additional conditions with user-defined speeds.
Added support for Array Microphone Type 4957 in the Array Acoustics Measurement and Post-processing suite of applications.
PULSE Sound Power: In the Directive 2000-14 template, using a parallelepiped geometry, it is now possible to enter a user-defined measurement distance.
PULSE Array Acoustics Suite: Support for Array Microphone Type 4957 in Acoustic Test Consultant
PULSE OMA: Enhancements have been implemented from more flexible and faster workflow to improved algorithms. For a detailed history of enhancements and bug fixes please look in the Version History in the PULSE OMA Help system. The latest Help system can be download from Preferences > Help in the Start menu.
LabShop LAB-6569:Fixed: Can connect with LAN-XI Wireless Frame Type 3660-A-200 without drop-out.
LabShop LAB-6677:Fixed: PULSE Signal Player works now with many channels after a major software upgrade.
LabShop LAB-6734:Fixed: GADI now works for LabShop with 8404-NS license
LabShop LAB-6736:Fixed: 8 families of HBK-branded Dytran transducers have been added to the transducer database.
Front-end Setup LAB-6738:Fixed: Reduced start-up time for Front-end Setup program.
LabShop LAB-6744:Fixed: LabShop can only read BKC files containing integer data. An error message now appears when a BKC file contains float data.
Array Acoustics Suite AAS-4306:Fixed: The post-processing application now launches without issue.
Refined Beamforming Calculations AAS-4307:Fixed: Calculations with NNLS and mirror ground are working as normal.
Array Acoustics AAS-4308:Fixed: For sound intensity, field checks are now done at max bands.
Array Acoustics Suite AAS-4309:Fixed: Added support for Array Microphone Type 4957 in ATC and array acoustics post-processing
BKCSV-317:Enhancement: Added date and time to measurements in result table.
BKCSV-330:Fixed: Added support for CAN signals.
BKCSV-349:Fixed: Added ambient noise correction for the R51 standard.
BKCSV-351:Fixed: Added 05 Series of Amendments to UN Regulation No. 41 (Noise Emissions of Motorcycles).
BKCSV-337:Fixed: Added support for R51 Revision 03 Amendment 10.
PULSE Electroacoustics LAB-6733:Fixed: The PULSE SSR Analyzer Equalization Function has been updated to work in latest PULSE versions.
Earth-moving Machinery SP-1488:Fixed: Workaround found applying a new template to minimize the slow-down of the software.
PULSE Sound Power SP-1517:Fixed: The constant for the triple point of water has been corrected in order to correct for humidity according to ISO 3745.
PULSE Sound Power SP-1520:Fixed: When measuring according to ISO 3744 using a parallelepiped measurement surface, a warning is no longer shown when the directivity index on specific microphone is lower than average.
PULSE OMA:For a detailed history of enhancements and bug fixes please look in the Version History in the PULSE OMA Help system.
Accelerate your product innovation with HBK solutions in virtual, physical and in-process testing. From the electrification of mobility to the advancement of smart manufacturing, we support you throughout the entire product lifecycle, sharing your mission for a cleaner, healthier, and more productive world.