See All Software See All Aufnehmer See All Elektroakustisch See All Akustische End-of-Line-Testsysteme See All Vibration Testing Equipment See All Systeme und Datenerfassung See All Akademie See All Anwendungen See All Industrien See All Services See All Support See All Sustainability See All Our Business See All Our History See All Careers See All Globale Präsenz
arrow_back_ios

Main Menu

See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Inertial Sensor Software See All Acoustic See All Current / voltage See All Displacement See All Schwingungserreger See All Force See All Inertialsensoren See All Wägezellen See All Pressure See All Smarte Sensoren mit IO-Link-Schnittstelle See All Strain See All Torque See All Vibration See All Testlösungen See All Aktoren See All Verbrennungsmotoren See All Betriebsfestigkeit See All eDrive See All Sensoren für Produktionstests See All Getriebe See All Turbolader See All LDS-Shaker-Systeme See All Leistungsverstärker See All Schwingungsregler See All DAQ Systeme für die mechanische und Struktur-Analyse See All DAQ-Systeme für Sound & Vibration&V See All Industrie-Elektroniken See All Leistungsanalysator See All Handgehaltene Geräte für Schall und Schwingung See All Drahtloses Datenerfassungssystem See All DAQ Systeme für die mechanische und Struktur-Analyse See All Schulungskurse See All Akustik See All Anlagen- und Prozessüberwachung See All Elektrische Energie See All Kundenspezifische Sensoren See All NVH See All Zuverlässigkeit See All Smarte Sensoren See All Schwingbelastung See All Strukturelle Integrität See All Automobil & Bodentransport See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Our People See All Compliance
arrow_back_ios

Main Menu

See All BK Connect / PULSE See All API See All Microphone sets See All Cartridges See All Spezialmikrofone See All Akustische Kalibratoren See All Mikrofon-Vorverstärker See All Schallquellen See All Zubehör für akustische Sensoren See All Accessories See All Leistungsverstärker See All Zubehör für Schwingprüfsysteme See All Accessories See All Bending / beam See All Zubehör für Wägezellen See All DMS für die Experimentelle Spannungsanalyse See All DMS für den Aufnehmerbau (OEM) See All Zubehör für Dehnungsmessstreifen See All Nicht rotierend (Kalibrierung) See All Rotierend See All CCLD (IEPE)-Beschleunigungssensor See All Ladungs-Beschleunigungssensor See All Impulse hammers / impedance heads See All Drehzahlsensoren See All Kabel See All Accessories See All QuantumX See All SomatXR See All MGCplus See All Optische Interrogatoren See All CANHEAD See All LAN-XI See All Fusion-LN See All Zubehör für Industrieelektroniken See All GenHS See All Zubehör für GenHS See All Software für handgehaltene Geräte See All Zubehör für handgehaltene Geräte für Schall und Schwingung See All Drahtlose DAQ Gateways See All Drahtlose DAQ-Knoten See All Elektroakustik See All Schallquellenortung See All Umgebungslärm See All Produkt-Lärm See All Schallleistung und Schalldruck See All Vorbeifahrgeräusche See All Strukturüberwachung See All Produktionsprüfung und Qualitätssicherung See All Maschinenanalyse und -diagnose See All Strukturüberwachung See All Batterieprüfung See All Einführung in die Messung elektrischer Leistung bei transienten Vorgängen See All Transformator-Ersatzschaltbild | HBM See All Strukturelle Dynamik See All Prüfung der Materialeigenschaften See All Sicherstellung der strukturellen Integrität von Leichtbaustrukturen See All Elektrifizierung von Fahrzeugen See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Performing Derating Analysis

Most equipment failures are precipitated by stress. When the applied stress exceeds the inherent strength of the part, either a serious degradation or a failure will occur. To assure reliability, the equipment must be designed to endure stress over time without failure. In addition, design stress parameters must be identified and controlled, while parts and materials that can withstand these stresses must be selected. Derating standards are used to help you select and use parts and materials so that the applied stress is less than rated for a specific application.

In ReliaSoft Lambda Predict, derating analysis is available only for systems analyzed with the MIL-217, Bellcore/Telcordia or FIDES prediction standards. In this example, we will analyze the effect of ambient temperature on a particular system.

The example file contains sample system configuration data for MIL-217, Bellcore/Telcordia and FIDES systems. You can open any of the sample projects, but only the systems that are analyzed with the prediction standard you have purchased will be displayed. To demonstrate derating analysis, we will use the MIL-217 system as an example. The instructions are generally the same for all systems (unless noted otherwise), so you can follow along with the example regardless of which system is available to you.

Analysis

 

For each component that can be derated, the Properties tab shows the properties that will affect both the component's failure rate and derating, while the Derating tab shows additional properties that apply only to derating analysis. As an example, the following picture shows the properties of a ceramic capacitor in the MIL-217 system in the sample project.

Step 1: Before starting the analysis, we must configure the system hierarchy to display results from a derating analysis. To do this, right-click anywhere in the system hierarchy and then choose Customize Columns on the shortcut menu. In the window that appears, select the Derating Status and Derating check boxes, and then click OK to display those columns in the system hierarchy.

 

Step 2: In the prediction folio, select the top-level item and choose Prediction Tools > Derating > Apply Derating.

Select the NAVSEA derating standard from the drop-down list and click OK. The application will then automatically evaluate each component to determine whether it meets the requirements provided by the selected derating standard. The results are displayed in the Derating column, as shown next. (Note that any components of types not specified in the derating standard are not considered in the derating analysis.)

Aside from the results shown in the Derating column, icons are also displayed to indicate the status of the component:

 A green icon (Not Stressed) indicates that the component meets the derating requirements defined in the standard (i.e., the stress level and temperature fall within the nominal case curve).

 A blue icon (Exceeds Nominal) indicates that the component does not meet the derating requirements, but it is not overstressed (i.e., the stress level and temperature fall outside the nominal case curve, but are within the worst case curve).

 A red icon (Stressed) indicates that the component is overstressed according to the derating requirements (i.e., the stress level and temperature fall outside the worst case curve or, in the case of a component with only a nominal case curve defined, outside the nominal case curve).

Notice that the capacitor displays the blue icon, indicating that the component, while not stressed now, is close to the stress limit.

 

Step 4: To plot the derating curves, select the capacitor and then choose Prediction Tools > Derating > View Component Derating.

The following plot shows that the capacitor's voltage stress ratio (blue dot) is between the nominal curve (green curve) and the worst case curve (red curve). This means that the capacitor does not meet the derating requirements, but is not actually overstressed. From the plot, we can assume that altering the ambient temperature will not address the problem. Instead, the voltage stress must be reduced.

The information on the plot's control panel helps to give you an idea on what value would be appropriate for the capacitor's voltage stress. According to this data, the nominal voltage stress for a temperature range of 0 to 110 degrees is 0.4. (Note that these values may differ for the Telcordia and FIDES sample systems.)

 

Step 5: Close the Component Derating window and return to the prediction folio. Select the capacitor and, in the Properties panel, change the value of the Voltage Stress property from 0.8 to 0.39. Press ENTER or click outside the field to accept the change.

 

Notice how the capacitor's derating status icon has changed from blue to green. This means that the capacitor now meets the derating requirements and is no longer stressed.

 

Step 6: Plot the capacitor's derating curves again. This time, the plot shows that the voltage stress is within the nominal case curve, as shown below.