AP402I

Anschlussplatte für 4 Spannungen, Lemo

4 channel connection board for voltages (±1 V, ±10 V, ±60 V) and currents (±20 mA)
TEDS Transducer identification
Supply voltage for active transducers can be chosen by jumpers: +5V, +8V, +16V
Max. 1 A for external sensor supply
Electrical isolation typ. 500 V
Transducer connection: Lemo-FCG6 socket
Usable with amplifier type ML801B (up to 2 AP402i per ML801B)
Width: 4 divs

img

Anschlussplatte für 4 Spannungen, Lemo

expand_more
chevron_left
chevron_right
MGCplus - Datenblatt Data Sheets German
MGCplus - Kurzanleitung Quick Start Guide English, Italian, French, Chinese, Korean, German, Spanish, Japanese
MGCplus - Betrieb mit Rechner oder Terminal Manuell German
Key attributes: DAQ Systems
Anzahl der Eingänge 4
Eingang Electrical voltage, Electrical current
Ausgang None
Interface TCP/IP
Genauigkeitsklasse 0.1
Schutzart IP20
Messrate 4.8 kHz
Gehäuse Standalone, Frame
Echtzeitfähigkeiten None