MX1609KB

QuantumX 16‑channel Thermocouple Type K Amplifier

16 electrically isolated input channels supporting thermocouple type K (NiCr-NiAl) sensors. Each channel can be individually configured to measure temperatures precisely with an accuracy of up to ± 0.5 K.

img

QuantumX 16‑channel Thermocouple Type K Amplifier

expand_more
chevron_left
chevron_right

MX1609KB: High‑precision Temperature Measurements

The MX1609KB is a 16‑channel thermocouple amplifier designed for accurate and interference‑resistant temperature measurements. As part of the QuantumX family, it delivers exceptional precision, seamless system integration, and the flexibility needed for demanding R&D environments.

Key features

  • High‑precision temperature measurement with accuracy up to ±0.5 K
  • Fast response with sampling rates up to 600 Hz per channel for dynamic applications
  • 16 galvanically isolated channels with individually optimized cold junctions enabling exact measurement results
  • Advanced signal conditioning, including Bessel and Butterworth low‑pass filters
  • TEDS support for automatic sensor identification
  • Robust connectivity via Ethernet (PTP) and FireWire for easy system integration
  • Factory calibration data stored on the device according to ISO10012

Real-time data acquisition of temperature measurements

The MX1609KB is optimized for type K thermocouples, covering a wide temperature (linearization) range from –100 to +1300 °C/–148 to +2372 °F. With internal cold junctions for each input, you are ensured maximum accuracy, while active low‑pass filtering provides clean, interference‑free signals. With up to 600 Hz per channel, the module captures rapid temperature changes with clarity, making it ideal for dynamic thermal analysis.

Typical applications

  • Highly dynamic temperature measurements in research and development
  • Climate chamber testing and complex thermal modeling
  • Multidimensional temperature mapping using 16 individually scalable channels
  • Fast‑changing thermal processes requiring high sampling rates and low noise

Fast, easy integration

All applications benefit from the module’s precision, electrical isolation, and seamless integration into larger QuantumX systems. And due to its wide range of connection options, Ethernet, FireWire, PROFINET and EtherCAT, you are sure of optimal connectivity and effortless system integration. But it is the integrated TEDS capability, where the module automatically identifies connected sensors, that allows you to streamline setup and minimize configuration time.

Comparable modules

The MX1609 series offers top quality with an outstanding price-to-performance ratio. For comparison, the MX1609TB version supports type T thermocouples,

For more challenging tasks in an electrical environment, the QuantumX MX809B insulated thermocouple amplifier is available.

Stay connected with the latest firmware and software

All QuantumX modules are delivered with the latest firmware. For existing modules, it is easy to update the firmware by simply downloading the latest firmware package.

HBK also provides both native and third-party software packages and drivers allowing you to fully leverage the QuantumX ‘open’ data acquisition infrastructure for integration with a great number of operating, analysis and automation software. This includes:

  • MX Assistant: a modern and free device or system assistant that supports all module functions
  • catman®EASY / AP / Enterprise: The standard DAQ software used with the QuantumX platform
  • Third-party drivers: For example, LabVIEW™, Visual Studio® .NET and CANape®

Go to our download site for more information and a complete list of options.

Did you know? You can also connect Tescia data acquisition software to your QuantumX module via the MX Assistant utility. Talk to one of our experts to find out more.

Language keyboard_arrow_down
QuantumX MX1609KB - Data Sheet Data Sheets English
MX410 - Quick Start Guide Quick Start Guide English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese
QuantumX - Operating Manual Manual/Operating manual English
MX1609KB - Data Sheets Data Sheets Chinese
MX1609KB - Data Sheets Data Sheets Japanese
MX1609KB - Data Sheet Data Sheets German
QuantumX - Operating Manuals Manual/Operating manual Japanese
QuantumX - Operating Manuals Manual/Operating manual German
QuantumX - Operating Manuals Manual/Operating manual Chinese

Sales documents

QuantumX - Brochure Brochure English
QuantumX - Brochures Brochure German
QuantumX - Brochures Brochure Portuguese
QuantumX - Brochures Brochure Chinese
QuantumX - Brochure Brochure Japanese

Certificates and Approvals

QuantumX - EU Declaration of Conformity Declaration of Conformity English
MX1609KB - CAD CAD Step Files
MX1609KB-R - CAD CAD Step Files
Key attributes: DAQ Systems
Number of inputs 16
Input Thermocouples
Output None
Interface TCP/IP, Firewire
Accuracy class 0.7
Degree of protection IP20
Sample rate 500 Hz
Housing Standalone
Real-time capabilities None