The QuantumX platform combines optical and electrical measurements in a single, reliable, and scalable solution. At its core, the MXFS module is designed for Fiber Bragg Grating (FBG)-based sensors, bringing all the benefits of BraggMETER technology to your data acquisition setup for easy, flexible, and cost-effective optical measurements.
BraggMETER technology ensures exceptional precision through continuous swept laser scanning, while a built-in wavelength reference provides continuous calibration for long-term accuracy. Its broadband tuning range of 100 nm with parallel optical connectors enables seamless integration of large sensor networks.
With MXFS modules, hundreds of FBG sensors can be connected in series across eight optical connectors, enabling synchronized acquisition. This makes the system perfect for large-scale sensing networks, delivering accurate and stable measurements for sensors with high strain capability, fatigue resistance, and long-distance installation—all while reducing cost per measuring point and simplifying ownership through a unified platform.
Two module options for your application:
Two connector types for adaptability:
Combines synchronized optical and electrical measurements in one modular DAQ system. Fully integrated with HBK software solutions for data acquisition and analysis, including MX Assistant, CommonAPI, and catman® software. Drivers for third-party platforms, such as LabVIEW, are also available.
Connect hundreds of FBG sensors across eight optical connectors to build large-scale networks. Expand functionality by adding additional modules, optical or electrical, for expanded and hybrid measurement setups. Integrate seamlessly through multiple communication platforms and protocols, and create analog outputs for flexible system configurations.
Reduces cost per measuring point and simplifies ownership by using a single, unified platform.
| QuantumX MXFS DI - Data Sheet | Data Sheets | English |
| MXFS SI - Data Sheet | Data Sheets | English |
| MXFS DI - Data Sheets | Data Sheets | Japanese |
| MXFS DI - Data Sheets | Data Sheets | Chinese |
| MXFS DI - Data Sheets | Data Sheets | German |
| MXFS DI - Data Sheets | Data Sheets | Spanish |
| MXFS DI - Data Sheets | Data Sheets | French |
| MXFS SI - Data Sheet | Data Sheets | Japanese |
| MXFS SI - Data Sheet | Data Sheets | Chinese |
| MXFS SI - Data Sheet | Data Sheets | Spanish |
| MXFS SI - Data Sheet | Data Sheets | French |
| MXFS SI - Data Sheet | Data Sheets | German |
| MXFS QuantumX BraggMETER Module - User Manual | Manual | English |
| MXFS - Operating Manuals | Manual | German |
| MXFS - Operating Manuals | Manual | French |
| MXFS - Operating Manuals | Manual | Chinese |
| MXFS - Operating Manuals | Manual | Japanese |
| MXFS - Operating Manuals | Manual | Spanish |
| QuantumX MXFS - Safety Instructions | Safety Instructions | English, French, German |
Certificates and Approvals
| Quality Assessment Report Summary IECEX: DE/PTB/QAR14.0003/03 | Certificates | English |
| HBK FiberSensing, S.A., EN IEC 60079-0-0:2018, EN 60079-28:2015 | Certificates | English |
| MXFS - CE Declaration of Conformity | Declaration of Conformity | English, Italian, French, Portuguese, Chinese, German, Spanish, Japanese |
| MXFS - UKCA Declaration of Conformity | Declaration of Conformity | English, Italian, French, Portuguese, Chinese, German, Spanish, Japanese |
| FiberSensing, IECEX Certificate of Conformity: BVS 24.0014 | Declaration of Conformity | English |
| Input | Fiber Bragg Grating |
| Number of connectors | 8 |
| Resolution | 0.5 pm, 1 pm |
| Housing | Standard, Backplane, Stackable |
| Sample rate | 100 S/s, 2000 S/s, 1 S/s, 10 S/s |
| Interface | EtherNET I/P, Firewire |
| Connector type | FC/APC, SC/APC |
| Degree of protection | IP20 |
| Number of inputs | 8 |
| Input | Fiber Bragg grating |
| Output | None |
| Interface | TCP/IP, Firewire |
| Accuracy class | n/a |
| Degree of protection | IP20 |
| Sample rate | 100 Hz, 2000 Hz, 1 Hz, 10 Hz |
| Housing | Frame, Rack with PC, Standalone |
| Real-time capabilities | None |
List of accessories available for all variants of this family
HBK offers the complete product portfolio for your monitoring application: With newLight optical sensors, strain, temperature, acceleration, load and tilt measurements are possible. In addition, QuantumX MXFS is compatible with the powerful HBK catman software but also open to other software.
Like all QuantumX modules, MXFS is compatible with catman data acquisition software (DAQ) – version 5.4 or higher –, allowing for data visualization, analysis and storage during the measurement and subsequent reporting.
The software has an extensive range of functionality and is easy-to-use, even for users who are unfamiliar with the technology.
Using catman with MXFS as stand-alone or in a measurement chain that acquires data via different QuantumX modules, the software benefits your measurement in every way:
The catman licence is already pre-installed on the module. Nevertheless, MXFS is open to any software by modern API and LabVIEW driver.
Free white paper
Did you already know that HBM has been developing optical interrogator systems since 2004?
Always trying to achieve the best possible results, our experts have regularly improved the interrogators over the past 16 years.
The transformation has not only made the interrogators smaller and and more lightweight but also significantly improved the devices' speed thus increasing both accuracey and the range of applications.
Don’t miss the evolution of the optical interrogators and see how QuantumX MXFS became what it is. Learn more