MAIN MENU

MX809-PAKEASY

QuantumX package: MX809B + catmanEASY

Product package including:
8-channel measurement module of the QuantumX family
for isolated temperature measurement using
thermocouples or for measurement of cell voltages
(5V);
Supports the following transducer technologies:
- Thermocouple types K, J, T, B, E, N, R, S, C with
internal cold junction for each channel;
- Electric voltage ± 5 V (copper socket);
For each measurement channel:
- Electrical insulation in accordance with EN60664:
1000 V, transient-proof up to 2500 V
(against other channels, electrical supply,
communication, housing)
- Measurement categories (safety): CAT II 600 V,
CAT III 300 V;
- Sample rate: up to max. 600 S/s;
- 24 bit ADC;
- Adjustable digital low pass filter: Bessel,
Butterworth, linear phase;
- Socket: Thermo Mini (male, copper contact)
prepared for insulating cap from HBM;
General:
- For temperature measurement on components that
conduct high voltage;
- Suitable for mobile and stationary applications
with electrical components;
- 1 x Ethernet, 2 x Firewire;
- Voltage supply: 10...30 V DC, max. 6 W;
- Factory calibration data in accordance with
DIN/ISO 10012 saved on the device (generate
certificate using MX Assistent)
Product bundle is 10% discounted and also includes:
- Power supply (1-NTX001);
- 8 insulating caps for Thermo Mini (1-CON-A1018);
- Ethernet cross-over cable (1-KAB239-2);
- catman Easy software from HBM + Software
maintenance (12 months).

img

QuantumX package: MX809B + catmanEASY

expand_more
chevron_left
chevron_right

QuantumX MX809B: Maximum Safety at a High Potential

The new QuantumX MX809B module provides eight channels for the measurement of temperatures and voltages at a high potential. Every channel supports all customary thermocouples such as type K, J, N, T, E, and many others as well as, in general, voltages in the range of +/- 5 V. The module offers an innovative insulation concept to meet all safety requirements: Double-insulated measuring leads and standard thermo Mini connectors (IEC, ANSI) as well as a patented contact protection and safety concept (insulating cap) prevent direct contact with hazardous live parts to ensure highly reliable measurement.

Typical fields of applications for the MX809B include the testing and analysis of electric motors, generators, rectifiers or inverters, chargers, and, in particular, energy storage systems (high-voltage batteries) and fuel cells. In battery tests, the amplifier allows for precise measurement of minimal cell voltages and temperatures at a potential of up to 1,000 V. Safety is guaranteed even with voltage peaks of up to 2,400 V. Other modules of the QuantumX series can be added as desired. The complete system is ideally suited for use in the field and in the laboratory. 

To make measurement results reliable and dependable, the calibration of transducers, amplifiers, or complete measurement chains is required. For QuantumX, the working standard calibration certificate according to ISO 10012 is stored in the module. The DAkkS certificate (ISO 17025) from HBM is available on request.

 

catman®Easy

catmanEasy is the basic version of the catman Data Acquisition Software which includes online and offline setup, online visualizations, and online maths as well as recording functionalities. catman Easy can be combined with two different add-on modules:

  • EasyMath: Mathematics module and auto sequences for catman Easy.
  • EasyScript: Free programming under VBA in measurement and analysis mode.

Maximum safety

  • Innovative insulation and safety concept
    • Double-insulated measuring leads
    • Standard thermo Mini connectors (IEC, ANSI)
    • Patented contact protection and safety concept (insulating cap)
  • VDE tested and certified 

Unique coupling concept preventing direct contact with hazardous live parts to ensure highly reliable measurement

Flexibility

  • For test bench and mobile road tests
  • Thermocouple type immediately visible due to transparent insulating cap
  • Easily extensible with MX403B:
    • Voltages in the range of +/- 10, 100 or 1,000 V in measurement categories II and III
    • Current measurement via plug-on burden or current clamp
    • Basis for total harmonic distortion (THD) analysis
  • Coupling can be connected and disconnected by the user

Flexibility to meet varying requirements thanks to the possibility of defining the sensor’s cable length and implementing the wiring as required in advance

Ease of integration

  • Connection via Ethernet to a PC
  • Reliable catman software support
  • Integration with other software (.NET API), LabVIEW™ or CANape
  • Real-time integration of measurement signals (CX27B) into automated test runs via EtherCAT

Both centralized and distributedmodules allow for easy and individual integration

Language keyboard_arrow_down
QuantumX MX809B - Data Sheet Data Sheets English
MX809B - Data Sheets Data Sheets French
MX809B - Data Sheets Data Sheets German
MX809B - Data Sheets Data Sheets Japanese
MX403B - Operating Manuals Manual English, French, German

Certificates and Approvals

QuantumX MX809B - EU Declaration of Conformity Declaration of Conformity English
Key attributes: DAQ Systems
Number of inputs 8
Input Thermocouples, Electrical voltage
Output None
Interface TCP/IP, Firewire
Accuracy class 0.02
Degree of protection IP20
Sample rate 500 Hz
Housing Standalone
Real-time capabilities None