AP402I

Connection board, for 4 sockets Lemo

4 channel connection board for voltages (±1 V, ±10 V, ±60 V) and currents (±20 mA)
TEDS Transducer identification
Supply voltage for active transducers can be chosen by jumpers: +5V, +8V, +16V
Max. 1 A for external sensor supply
Electrical isolation typ. 500 V
Transducer connection: Lemo-FCG6 socket
Usable with amplifier type ML801B (up to 2 AP402i per ML801B)
Width: 4 divs

img

Connection board, for 4 sockets Lemo

expand_more
chevron_left
chevron_right
MGCplus - Data Sheet Data Sheets English
MGCplus - Quick Start Guide Quick Start Guide English, Italian, French, Chinese, Korean, German, Spanish, Japanese
MGCplus - Operation with computer or terminal Manual English

Certificates and Approvals

MGCplus - EU Declaration of Conformity Declaration of Conformity English
Key attributes: DAQ Systems
Number of inputs 4
Input Electrical voltage, Electrical current
Output None
Interface TCP/IP
Accuracy class 0.1
Degree of protection IP20
Sample rate 4.8 kHz
Housing Standalone, Frame
Real-time capabilities None