MAIN MENU

WA-T

The WA-T probe-style displacement transducers combine exceptional robustness with high measurement precision. They are ideal for accurate dimensional measurements and provide reliable data in a wide range of test rigs, laboratory environments, and experimental setups. A pressure resistant version is also available, enabling precise measurements in hydraulic cylinders or similar demanding applications.

NEW: Available with IO-Link Interface

img

WA-T

expand_more
chevron_left
chevron_right

WA-T: Precise Inductive Displacement Measurements up to 100 mm

The proven WA-T probe-style displacement transducers are based on the differential inductive bridge principle and utilize a quarter-bridge circuit. The bridge is completed within the sensor to form a full bridge circuit, enabling straightforward connection to a bridge amplifier. For even simpler integration, the WA-T is also available with an integrated inline amplifier.

Built for demanding industrial environments, WA-T sensors are hermitically sealed to protect against dirt, humidity  and contamination. The displacement transducers combine rugged mechanics with excellent temperature stability, ensuring reliable performance under challenging conditions. The spring-loaded probe pin automatically maintains contact with the measurement object, reducing installation effort. Based on the proven inductive bridge principle, WA-T sensors deliver exceptional long term stability.

New: Inline amplifier options available. Choose from:

  • 4 – 20 mA current output
  • 0 – 10 V voltage output
  • IO-Link digital interface

Configure your WA-T+ Sensor here.

Key features:

  • HBK accuracy class: 0.2
  • Accuracy class 0.1 with inline amplifier versions
  • Measurement ranges: From 2 mm – 100 mm
  • Output signals: mV/V (passive), 0 – 10 V, 4 – 20 mA or IO-Link

 

Industry-standard interfaces for easy integration

Choose the interface that best suits your application. In addition to passive mV/V output, WA-T sensors can be supplied with voltage, current, or IO-Link outputs for simplified installation and improved measurement performance.

Benefits:

  • Minimized linearity error of 0.1%, if an inline amplifier option is chosen.
  • Digital version with IO Link interface includes peak detection, Bessel and Butterworth filters, limit switches and a digital output
  • Delivered as a calibrated measurement chain, just connect and start the measurement
  • With IO-Link: Immediate measurement values in millimeters when connected to an IO-Link master
  • Versions with IO-Link Interface: Lower installation and operating costs through faster mounting, no parameterization required, and reduced cabling costs.

Benefit from higher accuracy, easier installation, and lower system costs with the WA-T+ inline amplifier options.

Extensive configuration options

Available options:

  • Multiple cable lengths and connector versions
  • Straight or 90° cable / connector outlets
  • Plug mounting options, connectors, and TEDS available on request
  • Low temperature versions down to –25°C
  •  High temperature versions up to +150°C
  • More than 15,000 configuration combinations.

The result is a displacement transducer that can be precisely matched to your application requirements.

Built for harsh environments

  • Ruggedized mechanical construction
  • Hermetically sealed housing
  • Dirt-proof design
  • Protection ratings up to IP67 (depending on version)
  • High resistance to shock and vibration, tested to EN 60068
  • Reliable operation in demanding EMC environments

Reliable, long-term measurements with virtually no wear, ensuring maintenance-free operation even in the most demanding civil engineering applications.

Filter

close
Language keyboard_arrow_down
WA-T - Data Sheet Data Sheets English
WA-T - Datenblatt Data Sheets German
WA-T- Caractéristiques techniques Data Sheets French
WA-T - Prospetto dati Data Sheets Italian
WA-T - 數據表 Data Sheets Chinese
WA-T - Quick Start Guide Quick Start Guide English, Italian, French, Chinese, German
WA-T - Mounting Instructions Mounting Instructions English, Italian, French, Chinese, German

Certificates and Approvals

WA - EU Declaration of Conformity Declaration of Conformity English
WA - UKCA Declaration of conformity Declaration of Conformity English
WA-T/0...2 mm - CAD CAD Step Files
WA-T/0...10 mm - CAD CAD Step Files
WA-T/0...20 mm - CAD CAD Step Files
WA-T/0...50 mm - CAD CAD Step Files
WA-T/0...100 mm - CAD CAD Step Files
WA-T
Type/technology Inductive
Application Multi purpose
Measurement range 10 mm, 50 mm, 100 mm, 2 mm, 20 mm
Measurement range 0.394 in, 1.97 in, 3.94 in, 0.079 in, 0.787 in
Degree of protection IP67
Output signal Passive, Current (4-20mA), Voltage (0…10V), IO-Link
Mechanical connection Probe
Linearity deviation 0.2 %, 0.1 %
Shaft diameter 12 mm
Shaft diameter 0.472 in
Length 159 mm, 299 mm, 491.6 mm, 209 mm
Length 6.26 in, 11.8 in, 19.4 in, 8.23 in

List of accessories available for all variants of this family

Product Code Description
Displacement transducer WA mounting kit 1-WS/ZB12 Displacement transducer WA mounting kit
Measuring Insert  M 2/70H DIN878 3-6061.0003 Measuring Insert M 2/70H DIN878