arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

MX411B-R

SomatXR: Highly dynamic amplifier (4)

4 channel highly dynamic universal Amplifier of the SomatXR family
Support of:
- Current fed piezos: IEPE (CCLD / ICP)
- SG half or full bridge (DC or Carrier Frequency with 4.8 kHz)
- Inductive half or full bridge
- Piezoresistive full bridge
- Voltage (10 V)
- Current (20 mA)
Each channel offers:
- Sample rate: max. 100 kS/s (or 200 kS/s in 2 -channel operation)
- Adjustable low pass filter (Bessel, Butterworth,
Linear Phase)
- TEDS support: Automatic sensor identification
- Electrically isolated
- Socket: ODU 14-pin
General:
- IP65/IP67 protection class
- Very high vibration (10 g) and shock resistance
(75 g)
- 1 x Ethernet, 2 x Firewire
- Voltage supply: 10...30 V DC, max. 15 W
- Factory calibration data in accordance with
DIN/ISO 10012 saved on the device (generate
certificate using MX Assistant)

img

SomatXR: Highly dynamic amplifier (4)

expand_more
chevron_left
chevron_right

Do you want to analyze highly dynamic systems and get the maximum out of your measurement? Then SomatXR MX411B-R is the right amplifier for you. MX411B-R has four channels with a maximum sample rate of 100 kS/s per channel, which increases to 200 kS/s in two-channel mode.  That makes the amplifier ideally suited for highly dynamic acquisition and analysis of mechanical measurement quantities.

The following transducer technologies are supported by SomatXR MX411B-R:

  • Voltage (±10V)
  • Standardized current (±20 mA)
  • Full-bridge or half-bridge circuit strain gauges
  • Inductive full and half bridges, LVDT
  • Current-fed piezoelectric transducers (IEPE, ICP®)
  • Piezoresistive full bridges

Sample rates of up to 100 kS/s per channel combined with a high resolution of 24-bit – MX411B-R guarantees maximum accuracy. This fully and reliably meets the requirements for acquisition of highly dynamic forces and accelerations in harsh environments.

Typical fields of application

  • Mobile measurements and tests with off-highway vehicles (construction, agriculture and forestry)
  • Stationary measurements and tests on infrastructures, e.g. buildings
  • Field tests in harsh environments

Your benefits

  • Reliable measurement results even in harsh environments
  • Reduced wiring effort due to use of distributed modules
  • Digitization close to the sensor results in higher measurement quality

 

Flexible, modular and expandable

SomatXR modules can also be used in combination with other data acquisition systems (e.g. QuantumX). In just a few simple steps you can put together a highly individualized data acquisition system scaled to your specific needs. The modules communicate via Ethernet TCP/IP and are synchronized using IEEE 1588 (PTPv2). 

Professional software support

SomatXR users benefit from a powerful software package. Every measurement module can be connected to the PC and  catman measurement software via Ethernet. The ultra rugged CX22B-R data recorder allows stand-alone use in the field without a PC. This ensures that the data is easy to acquire, clearly visualized and smartly analyzed.

Highly precise and reliable

Reliable and dependable measurement results require the calibration of transducers, amplifiers, or complete measurement chains.

  • Working standard calibration certificate according to ISO 10012 stored in the SomatXR module
  • DAkkS certificate (ISO 17025) from HBM on request
Language keyboard_arrow_down
SomatXR MX411B-R - Data Sheet Data Sheets English
SomatXR MX411B-R - Data Sheets Data Sheets German

Sales documents

SomatXR - Brochure Brochure English
SomatXR - Brochures Brochure Japanese
SomatXR - Brochures Brochure Portuguese

Certificates and Approvals

SomatXR and accessoires - EU Declaration of Conformity Declaration of Conformity English
MX411B-R - CAD CAD Step Files
Key attributes: DAQ Systems
Number of inputs 4
Input Strain gauge full/half bridge, Inductive bridge, IEPE / CCLD, Standardized voltage (+/- 10V), Electrical current
Output None
Interface EtherNET I/P, Firewire
Accuracy class 0.05, 0.03
Degree of protection IP65/IP67
Sample rate 100000 Hz
Housing Standalone
Real-time capabilities None