See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Articles See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Accessories See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management
calibration torque 400kNm 008

Torque Transducers Calibration

The HBK calibration laboratory offers many advantages when calibrating your torque transducer from 0.2 N·m to 400 kN·m. HBK maintains the only private calibration laboratory worldwide that can offer you this service.

Traceable

ISO 17025 certification.

Direct traceability to the German National Metrology Institute (PTB).

Assessment of the calibration laboratory by independent experts at regular intervals.

Benefit from calibration certificates with minimal measurement uncertainty, directly traceable to the National Standard.

Precise

Calibration machines with minimal measurement uncertainty (in non-state calibration laboratories).

Dead-load machines (sensors are loaded with weights on a lever arm in the Earth’s gravity field) up to 25 kN·m, extraordinary for a private calibration laboratory.

Machine accuracy up to 0.008% .

Unique competence up to 400 kN·m with a measurement uncertainty of 0.1%.

Optimize your measurement uncertainty assessment using the actual transducer characteristics - instead of data sheet specifications only.

Individual

Choice of different calibration standards: 

DIN 51309.

VDI/VDE 2646.

Working standard calibration.

Measurement chain or sensor? DIN 51309 to meet the highest demands or VDI/VDE 2646? It's your choice. We will be happy to advise you!

calibration torque 400kNm 008

From 0.2 N·m to 400 kN·m

The HBK calibration laboratory offers many advantages when it comes to calibrating your torque transducer:

  • Torque calibration in the range from 0.2 N·m to 400 kN·m - an extremely wide range. HBK maintains the only private calibration laboratory worldwide that can offer you this service
  • Calibration of complete measuring chains (also of third-party products) - at no additional cost to you
  • Decades of experience (since 1977) in the calibration of torque transducers, torque sensors and torque measurement chains
  • From the cost-effective calibration of industrial sensors to the transfer standard that meets the highest demands 
  • Calibration of alternating torque as a working standard calibration

HBK Torque Calibration Services

  • DIN 51309
  • VDI/VDE 2646
  • DAkkS-DKD-R 10-5
  • Working standard calibration
Calibration Pyramid HBK EN

Decision Guide: The Right Calibration For Your Demands

chevron_left
chevron_right

If you want to know everything about your sensor:  Calibration in accordance with DIN 51309 requires measurements using the sensor in three varying mounting positions. In other words, the sensor is rotated by 120° in the machine in each case i.e. the torque transducer needs to be mounted and dismounted thrice. The following characteristics are obtained from a DIN 51309 calibration and specified in the calibration certificate: 

  • Exact output signal for each calibration step
  • Hysteresis values for each calibration step
  • Repeatability and reproducibility for one and for varying mounting positions for each calibration step
  • Creep behavior
  • Return to zero
  • Interpolation error (the measured value’s potential deviation from the cubic and linear approximation).
  • Classification in accordance with DIN 51309

Furthermore, the calibration certificate specifies the measurement uncertainty as defined in DIN 51309.  This calibration provides guaranteed proof that your torque sensor is traceable measuring equipment (as required by ISO 9001). Conformity assessment: HBK will identify whether a torque sensor is outside the data sheet specifications.

Best price-to-performance ratio with guaranteed traceability Calibration in accordance with VDI/VDE 2646 requires two series of measurement in one mounting position (as opposed to DIN 51309). The following sensor characteristics are obtained from this calibration and specified in the calibration certificate: 

  • Exact output signal for each calibration step
  • Optimized sensitivity (obtained from the increasing and decreasing series’ measured values, based on the least squares method)
  • Maximum linearity deviation 
  • Maximum relative reversibility error
  • Remanence value
  • Furthermore, the calibration certificate specifies the measurement uncertainty. The required reproducibility data are based on statistical values resulting from similar calibrations. Besides HBK products, the database comprises many third-party sensors. 

This calibration provides guaranteed proof that your torque sensor is traceable measuring equipment (in accordance with ISO 9001).  Conformity assessment: HBK will identify whether a torque sensor is outside the data sheet specifications.

HBK also offers a working standard calibration with individually selectable load steps.  The following sensor characteristics are obtained from this calibration and specified in the calibration certificate: 

  • Exact output signal for each calibration step
  • Remanence value
  • Conformity assessment: HBM will identify whether a torque sensor is outside the data sheet specifications.

Our recommendation: We recommend calibration in accordance with VDI/VDE 2646 which, at the same price, provides you with more information about your torque sensor than the working standard calibration. 

HBK offers the calibration of alternating torque in accordance with DAkkS-DKD-R 10-5. The following sensor characteristics are obtained from this calibration and specified in the calibration certificate: 

  • Exact output signal for each calibration step
  • Reference straight-line equation
  • Remanence value
  • Graphical representation of the deviation from the reference straight line

We will be happy to advise you. 


20 N·m Torque Calibration Machine

0.2 N·m to 20 N·m
For working standard calibration. Uncertainty of torque representation:
  • 0.2 N·m - 20 N·m: ±0.4 % of measured value
Torque steps: 0.2; 0.4; 0.5; 0.6; 0.8; 1.0; 1.2; 1.6; 2.0; 2.5; 3; 4; 5; 6; 8; 10; 12; 16; 20 N·m

200 N·m Torque Calibration Machine

2 N·m to 200 N·m
for DAkkS and working standard calibration. Uncertainty of torque representation:
  • 2 N·m - 200 N·m: ±0.04 % of measured value
Torque steps: 2; 4; 5; 6; 8; 10; 12; 16; 20; 25; 30; 40; 50; 60; 80; 100; 120; 160; 200 N·m

1 kN·m Torque Calibration Machine

5 N·m to 1000 N·m
for DAkkS and working standard calibration. Uncertainty of torque representation: 
  • 5 N·m - 1 kN·m : ±0.01 % of measured value
Torque steps: 5 N·m to 1000 N·m in steps of 1 N·m each.
null

20 kN·m Torque Calibration Machine

50 N·m to 20 kN·m
for DAkkS and working standard calibration. Uncertainty of torque representation:
  • 50 N·m - 200 N·m: ±0.04 % of measured value
  • 250 N·m - 20,000 N·m: ±0.02% of measured value
Torque steps: 50; 100; 150; 200; 250; 300; 400; 500; 600; 800 N·m; 1; 1.2; 1.6; 2; 2.5; 3; 4; 5; 6; 8; 10; 12; 16; 20 kN·m

25 kN·m Torque Calibration Machine

100 N·m to 25 kN·m
DAkkS and working standard calibration. Uncertainty of torque representation :
  • 100 N·m - 20 kN·m ± 0.008% of measured value
  • 20.1 kN·m - 25 kN·m ± 0.01% of measured value
Torque steps from 100 N·m to 25 kN·m in steps of 100 N·m each.

50 kN·m Torque Calibration Machine

500 N·m to 50 kN·m
for working standard calibration. Uncertainty of torque representation:
  • 500 N·m - 50 kN·m: ±0.2 % of measured value
Torque steps: 500 N·m to 50 kN·m

400 kN·m Torque Calibration Machine

3 kN·m to 400 kN·m
for DAkkS and working standard calibration.

Uncertainty of torque representation:

  • 3 kN·m - 400 kN·m: ±0.1 % of measured value

Torque steps: 3 kN·m to 400 kN·m in steps of 1 kN·m each.



Sample Calibration Certificates

You want to have a look at our calibration certificates? Sample calibration certificates for all measured quantities covered by the HBK calibration laboratory can be downloaded as a PDF file. 

null

ISO standards quality control assurance warranty business technology concept.; Shutterstock ID 1253334961

Long-term Quality Assurance of Measurement Results

Professional torque transducer calibration is a prerequisite for assuring the quality of your measurement results in the long term and is an integral part of your ISO9001 certification.

Recommended for You