See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Sensors See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Sustainability See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Wireless DAQ Systems See All Pinnae See All Accessories See All DAQ See All Drivers API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Inertial Sensor Software See All Acoustic See All Current / voltage See All Displacement See All Exciters See All Force See All Inertial Sensors See All Load Cells See All Pressure See All Smart Sensors IO-Link See All Strain See All Torque See All Vibration See All Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Training Courses See All Whitepapers See All Acoustics See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All Industrial Process Automation See All Machine automation control and navigation See All NVH See All Reliability See All Smart Sensors See All Structural Health Monitoring See All Vibration See All Weighing See All Automotive & Ground Transportation See All Robotics See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All Wireless Gateways See All Wireless Nodes See All BK Connect Pulse See All API See All Microphone sets See All Cartridges See All Special Microphones See All Acoustic Calibrators See All Microphone Pre-amplifiers See All Sound Sources See All Acoustic Transducer Accessories See All Accessories See All Power amplifier See All Accessories for exciters See All Accessories See All Digital load cells See All Accessories See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-Rotating Torque Transducers See All Rotary Torque Sensors See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Tachometer Probes See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Handheld S&V measurements See All Sound Power and Sound Pressure See All Noise Certification See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Infrastructures Monitoring See All Rail Monitoring See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Brüel & Kjær Downloads See All Software License Management

WA

Displacement transducer version WA

Inductive displacement transducer

Nominal sensitivity: 80 mV/V ± 1 %

Degree of protection: IP67

img

Displacement transducer version WA

expand_more
chevron_left
chevron_right

The K-WA is inductive displacement measurement in a compact design in plunger or probe type - ready to be configured in accordance with your needs

Find bellow some explanations to our options.

Version

The standard version of the WA is supplied in either detachable plunger version (L) or displacement probe version (T). The transducers are also adapted for high or low temperature conditions.

  • L = Detachable plunger, standard version
  • M = Detachable plunger, high temperature version up to max. 150 °C
  • T = Displacement probe, standard version
  • U = Displacement probe, high temperature version up to max. 150 °C
  • X = Displacement probe, low temperature version for -40 °C … 125 °C

Measuring range

The WA is available in five different measuring ranges: 0...2 mm (002W), 0...10 mm (010W), 0...20 mm (020W), 0...50 mm (050W) and 0...100 mm (100W).

The WA in probe type has three additional measuring ranges: 0...200 mm (200W), 0...300 mm (300W) and 0...500 mm (500W).

Type of connection at the transducer

The WA is supplied as standard with a 90° cable with IP67 protection (32K). On request, we can mount one of the following connectors to the transducer:

  • 31K = Pressure-resistant, M20x1.5 + fixed cable, IP67
  • 32K =  90°, fixed cable, IP67
  • 33K = 0°, fixed cable, IP67
  • 31S = Pressure-resistant, M20x1.5 + LEMO plug connection
  • 32S = 90°, LEMO male connector
  • 33S = 0°, LEMO male connector

Cable type

The standard version is PVC cable (SD). For high or low temperature versions, PTFE cable (max. 150 °C) is supplied (HT).

Cable ends

The WA is supplied as standard with a mounted cable with free ends (F1). All other cable ends can only be supplied if a rated output of 80 mV/V full bridge circuit is ordered.

  • D1 = DB-15P male connector
  • D2 = DB-15P male connector with TEDS
  • F1 = Free ends
  • M1 = MS 3106PEMV male connector
  • M2 = MS male connector with TEDS
  • Q1 = Sub-HD male connector
  • Q2 = Sub-HD male connector with TEDS

Non-linearity

Non-linearity options of 0.2 % (2) or 0.1 % (1) are available for the transducers.

NOTE: The 0.1 % non-linearity cannot be combined with the 0…10 mm measuring range and the 0.5...10 V rated output of the WA electronics.

Rated output

A rated output of 80 mV/V full bridge circuit is supplied as standard (8). An output of 0.5…10 V via WA electronics is only available if a transducer with a cable with free ends is ordered (2). If a non-linearity of 0.2 % is selected in addition to a free end cable, a PVC cable to the evaluator will be mounted to the transducer.

Cable length at transducer

The transducer is available with the following cable lengths: 3 m (3.00), 6 m (6.00), 10 m (10.00) and 20 m (20.00).

Cable length at WA electronics

The transducer with WA electronics is available with the following cable lengths: 1 m (1.00), 3 m (3.00), 6 m (6.00) and 10 m (10.00).

WA - Data Sheet Data Sheets English
WA - Mounting Instructions Mounting Instructions English, Italian, French, German

Certificates and Approvals

WA - EU Declaration of Conformity Declaration of Conformity English
Key Attributes: Displacement Transducers
Type/technology Inductive
Application Multi purpose
Measurement range 2 mm, 10 mm, 20 mm, 50 mm, 100 mm, 200 mm, 300 mm, 500 mm
Measurement range 0.079 in, 0.394 in, 0.787 in, 1.97 in, 3.94 in, 7.87 in, 11.8 in, 19.7 in
Degree of protection IP67
Output signal Passive, Voltage (+/- 10V)
Mechanical connection Loose plunger, Probe
Linearity deviation 0.2 %
Shaft diameter 12 mm
Shaft diameter 0.472 in
Length 124 mm, 154 mm, 159 mm, 209 mm, 214 mm, 299 mm, 330.6 mm, 491.6 mm, 530.6 mm, 730.6 mm, 1130.8 mm
Length 4.88 in, 6.06 in, 6.26 in, 8.23 in, 8.43 in, 11.8 in, 130 in, 194 in, 209 in, 288 in, 445 in