See All Simulação e Análise See All DAQ See All Drivers API See All Utilitário See All Controle de vibração See All Calibração See All DAQ See All Portátil See All Industrial See All Analisadores de potência See All Condicionadores de sinal See All Acústica See All Tensão e Corrente See All Deslocamento See All Força See All Células de carga See All Multicomponente See All Pressão See All Deformação See All Strain Gauges See All Temperatura See All Inclinação See All Torque See All Vibração See All Acessórios See All Controladores See All Excitadores de medição See All Excitadores modais See All Amplificadores de potência See All Sistemas Shaker See All Soluções de teste See All Atuadores See All Motores de combustão See All Durabilidade See All eDrive See All Sensores de teste de produção See All Caixas de transmissão See All Turbo Charger See All Acústica See All Monitorização de activos e processos See All Energia eléctrica See All NVH See All Sensores personalizados do OEM See All Integridade estrutural See All Vibração See All Transporte automotivo e terrestre
arrow_back_ios

Main Menu

See All nCode - Análise de Durabilidade e Fadiga See All ReliaSoft - Análise e gerenciamento de confiabilidade See All API See All Eletroacústica See All Ruído ambiental See All Identificação da Fonte de Ruído See All Ruído do produto See All Potência Sonora e Pressão Sonora See All Ruído de passagem de veículos See All Teste de produção e garantia de qualidade See All Análise e Diagnóstico de Máquinas See All Monitoramento de integridade estrutural See All Teste de bateria See All Introdução à Medição de Energia Elétrica Durante Transitórios See All Diagrama de circuito equivalente do transformador | HBM See All Sensores OEM para a indústria agrícola See All Sensores OEM para aplicações robóticas e de torque See All Dinâmica estrutural See All Ensaio das propriedades dos materiais

Teste de alto-falante inteligente - fala e audição

 

Voice-operated devices such as smart speakers have taken households by storm. With consumer satisfaction closely linked to how well smart speakers understand voice commands; speech intelligibility and overall sound quality are crucial factors in meeting today's customer demands.

Realistic Testing of Smart Speakers

An often-used method to measure response accuracy rate in voice-operated devices is called "RAR". The idea is to replay a recorded voice from a speaker in order to evaluate if and how often a voice command is recognized. However, as the directional character and frequency range of a human voice is different, this method can produce misleading results.

Smart speaker testing standards and requirements

In a room, good acoustics require a design that is fit for purpose, such as easy communication and a high degree of intelligibility in office spaces or long reverberation times in concert halls. Issues with acoustics are normally caused by sound being reflected too much, too little or in the wrong direction.

Speech and hearing simulation

To achieve the best result, Brüel & Kjær offers market-leading Mouth and Ear simulators, which provide highly accurate means to secure quality in testing of voice-operated products.

Brüel & Kjær’s High-frequency Head and Torso Simulator complies with key features defined in the ITU-T P.58 standard for Objective Measurement Apparatus.

High-Frequency HATS Type 5128

Capable of both issuing voice commands and measuring smart speaker response (full frequency range up to 20 kHz) makes fully automated testing of smart speakers and other voice operated devices possible.

Mouth Simulator Type 4227

Brüel & Kjaer's Type 4227 Simulator is a high-performance artificial mouth, which simulates the mode of diffusion of human speech.

The compactness and robustness of this artificial mouth is ideal for use in an R&D laboratory or on a test bench in production. Its design quality - compliant with ITU-T P.51 test standards - guarantees reliable and reproducible measurements, even over long periods.

Acoustic Dispersion

To reproduce a realistic human voice setup for smart speaker testing, acoustic speech dispersion comes into effect. Dispersion and attenuation of amplitude effects speech level in various angle and distance.

Brüel & Kjær’s High-frequency Head and Torso Simulator complies with key features defined in the ITU-T P.58 standard for Objective Measurement Apparatus, which defines attenuation values in relation to the Mouth Reference Point (MRP).*

*A position 25mm in front of the Lip Reference Plane (LRP) and defined in terms of dB attenuation relative to 65.3dB SPL at a distance of 500 mm in front of the MRP or 89.3 dB SPL at the MRP. Points are located on a circle centred at MRP and distributed in the horizontal plane at 0°, ±15°, ±30° and ±90° as well as in the vertical plane at ±15° and ±30°.