MAIN MENU

TYPE 4964

1/2" INFRASOUND MICROPHONE, PREPOLARIZED

1/2" INFRASOUND MICROPHONE, PREPOLARIZED

0.02Hzから20kHzの周波数帯域で高感度、高精度の音響測定用に特別に設計されたマイクロホンです。

TYPE 4964

TYPE 4964

expand_more
chevron_left
chevron_right

4964型マイクロフォンカートリッジは、高感度の低周波マイクロフォンを必要とする高精度の音響測定用に設計されています。TYPE4964は偏極型であるため、CCLDとクラシックプリアンプの両方で使用することができ、特にバッテリー駆動の機器や湿度の高い環境での使用に適しています。

  • 一般的なノイズ測定
  • 風力タービンの測定
  • ソニックブーム測定
Document タイプ 言語
½ inch Prepolarized Infrasound Microphone Type 4964 データシート English
TYPE 4964
プロパティ 値
Standard IEC 61094
Sound field Free field
Polarization voltage 0V
Sensitivity 50 mV/Pa
Lower limiting frequency 0.02 Hz
Higher limiting frequency 20 kHz
Inherent noise 14.2 dB(A)
Upper limiting of dynamic range 146 dB
Diameter 1/2 inch
Venting Rear
Minimum Temperature -30 °C
Maximum Temperature 150 °C
Minimum Temperature -22 °F
Maximum Temperature 302 °F

INFRASOUND AND FREE-FIELD RESPONSE

At infrasound and frequencies below a few kHz, the pressure and free-field response are the same. At higher frequencies, reflections and diffractions cause pressure to increase in front of a microphone's diaphragm.

Type 4964 has been optimized for free-field, and designed for use with the protection grid in place. Type 4964 is also suited for use in class 1 sound level meters and for all high-precision acoustic measurements where a robust and stable free-field microphone with an upper frequency of 20 kHz is required.

BUILD AND STABILITY

A press-fitted, stainless-steel diaphragm ensures superior longterm stability and mechanical robustness – Type 4964 will withstand the 1 m drop test of IEC 60068–2–32.

INDIVIDUAL CALIBRATION

As all Brüel & Kjær microphones, each Type 4964 is provided with an individual calibration chart including information about the open-circuit sensitivity, the frequency response in a free field as well as the electrostatic actuator response. Using the calibration data and the REq-X feature of LAN-XI, a real-time correction for different measurement situations can increase accuracy.