arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

TYPE 4190

1/2 "フリーフィールドマイクロスコープ、外部偏光

1/2 "フリーフィールドマイクロスコープ、外部偏光

20Hz~20kHzの周波数応答を持つ高感度を必要とする、高精度な測定のために設計された自由屋外マイクロホン。
img

TYPE 4190

expand_more
chevron_left
chevron_right

TYPE4190-L-001は、高感度のマイクが要求される高精度のフリーフィールド測定用に設計されています

  • 精密な音響測定
  • プレミアムクラスの騒音レベル計
  • IEC61672クラス1に準拠した機器
TYPE 4190
Standard IEC 61672
Sound field Free field
Polarization voltage 200V
Sensitivity 50 mV/Pa
Lower limiting frequency 3.15 Hz
Higher limiting frequency 20 kHz
Inherent noise 14.6 dB(A)
Upper limiting of dynamic range 146 dB
Diameter 1/2 inch
Venting Rear
Minimum Temperature -30 °C
Maximum Temperature 150 °C
Minimum Temperature -22 °F
Maximum Temperature 302 °F

USE OF FREE-FIELD MICROPHONES

At higher frequencies, reflections and diffractions cause a pressure increase in front of the diaphragm of a microphone. If not corrected for this would result in an increased output voltage.

A free-field optimisation means that the frequency response of the microphone has been designed in such a way that the free-field response at 0 degrees incidence is flat. This microphone is optimised for use with the protection grid in place.

Free-field microphones are commonly used for sound measurement in an anechoic chamber or far away from reflecting buildings, etc. Another area for free-field microphones is for general electroacoustic measurements like loudspeaker and microphone measurements.

Type 4190 is not only suited for use in class 1 Sound Level Meters but also for all high-precision acoustic measurements where a robust and stable, externally polarized free-field microphone with an upper frequency of 20 kHz is required.

STABILITY

A press-fitted, stainless-steel diaphragm ensures superior long-term stability and mechanical robustness – Type 4190 will withstand the 1 m drop test of IEC 60068-2-32.

POLARIZATION VOLTAGE

Type 4190 requires an external polarization voltage and must therefore be used with a classical preamplifier. Externally polarized microphones may be used at higher temperatures without severe changes in sensitivity.

Type 4190 is available in TEDS combinations with the classical Microphone Preamplifier Type 2669. The TEDS microphone is considered one unit and has been sealed in a clean environment.

The TEDS is programmed with the loaded sensitivity of the actual cartridge and the data is therefore readily available. The default TEDS template is to IEEE P 1451.4 but TEDS to IEEE 1451.4 is available on request.