PAD4002A-CAN

Elet.dig.aço inox.Cx.Conec./Conec.CAN

Eletrónica de transdutor digital
- Interface CANopen
- Sistema eletrónico adequado para transdutor de ponte inteira DMS
- Conexões robustas, M12, 8 polos
- Grau de proteção até IP68/69K, dependendo do conector utilizado
- 2 E/S digitais de programação livre
- Combinável com células de carga e transdutores de força analógicas
- sem certificado de calibração DKD

img

Elet.dig.aço inox.Cx.Conec./Conec.CAN

expand_more
chevron_left
chevron_right

PAD – The Perfect Connection for Analog Transducers and Load Cells to the Digital World

The PAD digital transducer electronics enables passive sensor types to be digitized based on the plug-and-play principle simply by using an M12-plug, thus allowing a cost-effective transition to the digital world. As an "electronics in a tube", the PAD comes in a compact stainless-steel enclosure and is, thus, ideally protected from liquids and dirt. Furthermore, the PAD offers maximum precision - even in demanding environments (up to IP68/IP69K degree of protection). 

  • Accuracy class: 0.01 with a test report for 6000 d, class III, IIII according to OIML R76
  • Interfaces: RS485 (4-wire, full-duplex) and CANopen

High measurement quality

With a measured value resolution of up to 5,120,000 digits for 2 mV/V and complete measurement signal conditioning with selectable or automatic filters, precision is guaranteed even with interference resulting from strong vibrations. IP68/IP69K degree of protection. Test report for 6000 d, class III, IIII according to OIML R76.

Reliable and stable readings even in harsh environments.

Plug & Play

The PAD can be easily connected to your load cell or other strain gauge sensors using an M12-plug. "Aseptic" applications can be implemented by combining it with PW27, PW29, and PW37 load cells. It can be installed close to the sensor or remotely in a control cabinet, depending on the application.

Universal and ready-to-use at an attractive price-to-performance ratio.

Convenient integration

The PAD transducer electronics can be conveniently integrated into various system environments using the RS485 (4-wire, full-duplex) and CANopen interfaces. The device is started via a PC and using the free PanelX software.

Easy transition to digital weighing technology.

Language keyboard_arrow_down
PAD - Folha de dados Data Sheets English
PAD - Folha de dados Data Sheets German
PAD400xA - Manual de operação Manual English, French, German

Certificates and Approvals

Ecolab material resistance Certificate - FIT5A/PW15.../PW25/PW37P/PW27B/PW27BP/PAD Certificates English
PAD - Declaração de conformidade Declaration of Conformity English
PAD4002A – CAD CAD Step Files
Key Attributes: Industrial Electronics
Number of inputs Single channel
Input Strain gauge full bridge
Interface CANopen, Digital IO
Clase de precisión 0.01
Sample rate 1200 S/s
Housing Field mounted
Internal logic None
Legal for trade Yes