3413A Vibration Transducer Data Sheets English
3413A
Type/technology Piezoelectric CCLD (IEPE)
Direction/Axes Triaxial
Measurement range 10000 m/s²
Measurement range 1000 g
Application General purpose
Weight 13 g
Weight 0.46 oz
Sensitivity tolerance 5 %
Sensitivity 5 mV/g
Lower frequency 3.3 Hz
Higher frequency 3 kHz
Minimum Temperature -50 °C
Maximum Temperature 160 °C
Minimum Temperature -60 °F
Maximum Temperature 320 °F
Mounting Adhesive mounting
Resonance frequency 20 kHz
Real-time capabilities None
Electric isolation Ground isolated
Output signal (connectivity) Analogue
Electrical connector location Side
TEDS No
Filtering None