TYPE 4954

1/4" FREIFELDMIKROFON, VORPOLARISIERT

Freifeldmikrofon für Messungen mit hohem Pegel und hoher Frequenz in einem Frequenzbereich von 4 Hz bis 100 kHz.

img

TYPE 4954

expand_more
chevron_left
chevron_right

Der Typ 4954 ist ein vorpolarisiertes 1/4" Freifeldmikrofon und wurde speziell für Hochfrequenzmessungen entwickelt.

Durch die Verwendung einer lasergeschweißten Edelstahlmembran und eines Schutzgitters aus Edelstahl ist dieses Mikrofon in der Lage, rauen Umgebungen standzuhalten.

  • Hochfrequenzmessungen
  • Hochpegelmessungen
  • Kostengünstige Messungen

Filter

close
FAMILY 4954
Standard IEC 61094, IEC 61672
Sound field Free field
Polarization CCLD, Classical
Sensitivity 2.8 mV/Pa
Lower frequency 16 Hz, 50 Hz, 3 Hz
Higher frequency 80 kHz, 22 kHz
Lower dynamic range 40 dB, 34 dB
Higher dynamic range 159 dB, 164 dB
Diameter 1/4 inch
Venting Side
Minimum Temperature -20 °C
Maximum Temperature 80 °C, 100 °C
Minimum Temperature -4 °F
Maximum Temperature 176 °F, 212 °F
Output signal (connectivity) Passive

This microphone consists of Microphone Type 4954 laser welded to a ¼" microphone preamplifier. The unit is assembled in a clean-room environment and sealed together, after which it is assigned one single type number and one single serial number. This means that the combined unit has better precision and long-time stability, and is handled as one complete unit.

The transducers can be connected to any CCLD input and support IEEE P1451.4 V0.9 TEDS (Transducer Electronic Data Sheet). The unit also contains TEDS, which means that information about the serial number, type and sensitivity is stored within it.

BENEFITS OF USING A MICROPHONE-PREAMPLIFIER SET:

  • Better stability and precision. Because the unit is assembled in clean-room facilities, there is no contamination.
  • Ease of use. Your analyzer front-end and software will automatically detect the type number, serial number and sensitivity because of the built-in TEDS technology. There is no need to enter this manually for every channel. 
  • Calibration integration. The TEDS technology means the microphone is automatically detected and identified by your data acquisition software, allowing it to be easily integrated with your calibration database.
  • Fewer errors. As your data acquisition software automatically knows the microphone type, serial number and sensitivity, manual inputs are greatly reduced – reducing human errors.