MAIN MENU

PAD4002A-RS4

Digit.Elektr.Edelst.Geh.Steck./Steck.RS4

Digitale Aufnehmer Elektronik
- RS485-Schnittstelle
- Elektronik geeignet für DMS-Vollbrückenaufnehmer
- Robuste Steckverbindungen, M12, 8-polig
- Schutzart bis zu IP68/69K, abhängig vom verwendeten Stecker
- 2 frei programmierbare digitale I/Os
- Kombinierbar mit analogen Wägezellen und Kraftaufnehmern
- kein DAkkS / DKD Kalibrierschein

img

Digit.Elektr.Edelst.Geh.Steck./Steck.RS4

expand_more
chevron_left
chevron_right

PAD – The Perfect Connection for Analog Transducers and Load Cells to the Digital World

The PAD digital transducer electronics enables passive sensor types to be digitized based on the plug-and-play principle simply by using an M12-plug, thus allowing a cost-effective transition to the digital world. As an "electronics in a tube", the PAD comes in a compact stainless-steel enclosure and is, thus, ideally protected from liquids and dirt. Furthermore, the PAD offers maximum precision - even in demanding environments (up to IP68/IP69K degree of protection). 

  • Accuracy class: 0.01 with a test report for 6000 d, class III, IIII according to OIML R76
  • Interfaces: RS485 (4-wire, full-duplex) and CANopen

High measurement quality

With a measured value resolution of up to 5,120,000 digits for 2 mV/V and complete measurement signal conditioning with selectable or automatic filters, precision is guaranteed even with interference resulting from strong vibrations. IP68/IP69K degree of protection. Test report for 6000 d, class III, IIII according to OIML R76.

Reliable and stable readings even in harsh environments.

Plug & Play

The PAD can be easily connected to your load cell or other strain gauge sensors using an M12-plug. "Aseptic" applications can be implemented by combining it with PW27, PW29, and PW37 load cells. It can be installed close to the sensor or remotely in a control cabinet, depending on the application.

Universal and ready-to-use at an attractive price-to-performance ratio.

Convenient integration

The PAD transducer electronics can be conveniently integrated into various system environments using the RS485 (4-wire, full-duplex) and CANopen interfaces. The device is started via a PC and using the free PanelX software.

Easy transition to digital weighing technology.

Sprache keyboard_arrow_down
Dokument Typ Sprache
PAD - Datenblatt Datenblätter English
PAD400xA - Bedienungsanleitung Handbuch/Bedienungsanleitung English, French, German
PAD - Datenblatt Datenblätter German

Certificates and Approvals

Dokument Typ Sprache
PAD - Konformitätserklärung Konformitätserklärung English
Ecolab material resistance Certificate - FIT5A/PW15.../PW25/PW37P/PW27B/PW27BP/PAD Zertifikat English
Dokument Typ
PAD4002A – CAD CAD-Dateien (STEP)
Key Attributes: Industrial Electronics
Eigenschaft Wert
Eichfähigkeit Yes
Anzahl der Eingänge Single channel
Integriertes Display No
Eingang Strain gauge full bridge
Interface RS485, Digital IO
Gehäuse Field mounted
Interne Logik None
Messrate 1200 S/s
Genauigkeitsklasse 0.01