MAIN MENU

FIT7A

The heart of a fast, precise and reliable checkweigher, being economically efficient, while also guaranteeing uniformity and compliance. It delivers real-time weight data of high-dynamic, fast and high-precision applications, making a fully traceable measurement to each individual product possible.

  • Ensuring precise results from 3 kg to 75 kg up to C6 accuracy class
  • Enabling quality control with a minimum verification interval (Y) up to 50.000
  • Fully traceable measurements with digital interface RS-485, CANopen or DeviceNet
  • Integrated overload protection up to 1000% of maximum capacity
  • Optional 2 sockets RS-485 version with 2 inputs, 4 outputs and diagnosis channel
img

FIT7A

expand_more
chevron_left
chevron_right

FIT7A Digital Load Cell: The Heart of Checkweighers

The future of checkweighing starts with the FIT7A digital load cell. With FIT7A, for the first time you can build your own checkweigher for your packaging line.  There is no need for you to purchase expensive components and you become more competitive and independent. 

Why opt for the checkweigher load cell from HBK? We are a pure supplier of weighing technology components. Therefore you do not purchase your components from your potential competitors. We are a dependable global partner offering high delivery reliability. Always near you: With a strong sales and service team that looks forward to providing personal support, answering your questions and offering professional training. 

Developed for Checkweighers

  • Extremely stiff design allows for higher throughput of your checkweigher, due to fast signal response and short filter times
  • Food-safe and corrosion-resistant stainless steel, resistant to strong detergents
  • Integrated electronics close to the sensor allows for maximum precision. Active temperature compensation guarantees precise results even in the event of temperature variations.
  • Maximum capacities from 3 kg to 75 kg available
  • Available with OIML accuracy class C3, C4 or C6 with Y up to 50.000

Robust

  • 1000% overload stability: Should it happen - the load cell even withstands cleaning crews stepping on it when working in a hurry
  • Excellent off-center load behavior: Suited for various conveyor sizes up to 600 mm length
  • IP 66 degree of protection up to the connector: Developed for wash-down applications involving the checkweigher being completely covered in foam
  • Connector instead of cable: Fast replacement in case of an emergency

Intelligent

  • FIT7A allows for stand-alone evaluation of light barriers and control of ejectors: No additional PLC is required
  • Tried and tested filter eliminates conveyor drive, roller and conveyor interference
  • Operation via free PanelX software: Saves valuable development time and supports you in optimizing your checkweigher

Filter

close
Language keyboard_arrow_down
FIT7A - Data Sheet Data Sheets English
Cables with connectors & connector plugs for analog and digital sensors; Data sheet; B03644 Data Sheets English
FIT-7A - Data Sheets Data Sheets Japanese
FIT-7A - Data Sheets Data Sheets German
アナログ/デジタルセンサ用コネクタ付きケーブル & コネクタプラグ; Data Sheet; B05092 Data Sheets Japanese
Câbles avec connecteur mâle & connecteur pour capteurs analogiques et numériques; Caractéristiques techniques; B03645 Data Sheets French
Patch Cable - Data Sheets Data Sheets German
AED / FIT - Application Note 012e: AED/FIT® Commissioning CANOpen Tech Notes English
Safety Instructions; FIT7A; A04828 Safety Instructions English, Italian, French, Portuguese, Chinese, German, Spanish
FIT-7A - Mounting Instructions Mounting Instructions English, Italian, French, German
MP85A Release Note Release Note English
A3390-10, CC-Link Manual/Operating manual Japanese
A3389, Gateway Manual/Operating manual French
PanelX - Operating Manuals Manual/Operating manual German

Certificates and Approvals

FIT7 - OIML Certificate Certificate English
FIT7 - Test Certificate Certificate English
FIT7A - EU Declaration of Conformity Certificate English, German
FIT7A - EU Declaration of Conformity Declaration of Conformity English
FIT7A - EU Declaration of Conformity Declaration of Conformity English
FIT7A 2 sockets capacity 3kg-75kg - CAD CAD Step Files
FIT7A 1 socket capacity 3kg-75kg - CAD CAD Step Files
AD112D - EDS File Device Description File (.ddf)
FIT7A
Type Single point
Application Dynamic Filling / Dosing, Checkweighing
Maximum capacity 10 kg, 3 kg, 20 kg, 5 kg, 30 kg, 50 kg, 75 kg
Maximum capacity 22.05 lb, 6.61 lb, 44.09 lb, 11.02 lb, 66.1 lb, 110.2 lb, 165.3 lb
Accuracy class C3, C4, C6
Degree of protection IP66
Minimum verification interval (Vmin) 1 g, 0.5 g, 2 g
Material Stainless steel with protective coating
Certification OIML
Maximum platform size 400 mm x 400 mm (15.7'' x 15.7'')