C9C Miniature Load Cell: For Measurement of Compressive Forces

The compact and cost-effective C9C type series force sensors reliably measure compressive force where space is limited. Due to their high fundamental frequency, they are suitable for very fast measurements. Like all strain gauge-based transducers, the C9C sensors also allow for static forces to be measured with long-term stability. They ensure both robustness and plug and measure solution due to their welded design from stainless steel and flexible to order concept. Available as passive load cell or with hard-wired inline amplifier with analogue or digital output signals. 

  • HBK accuracy class: 0.2
  • Capacities: 50 N ... 50 kN
  • Output signals: mV/V (passive), 0...10 V, 4 ...20 mA or IO-Link

 

New: With the new option "VAIO", the C9C comes along with an digital inline - amplifier and IO-Link interface. Your advantages:

  • Improved reliability: The Sensor Health monitoring of the C9C sends warnings in case of exceeding temperature or mechanical limits before problems occur.
  • More information: Statistical information such as number of sampels or mean value are available.
  • Lower costs, easy setup: The C9C with the VAIO option comes along as adjusted sensor. When connected to an IO-Link master, you will get immediately precise readings in Newton. Low cabling costs. 
  • Standard instrument features: Limit switches, peak detection, digital output, filter.
  • Fast: Internal sampling rate: 40 kHz, 0.9 ms cycling time to the IO-Link master.
  • Greater precision: Use your calibration and improve the linearity of your C9C.

 

Benefits of all C9C:

Small, dynamic and robust

  • Small diameter and flat design
  • Welded design from stainless steel; EMC-tested
  • High stiffness and small masses, leading to high fundamental frequency
  • Highly flexible cable, suitable for drag chains, resistance against most oils

Besides being compact, the sensor is robust, EMC-tested, and delivers reliable results. It is ideal for measuring fast processes.

Immediately ready for use

  • Various practical cable lengths, cable is suitable for drag chains and fuel-resistant
  • If chosen without in-line amplifier: TEDS available and available with a mounted plug for all HBK measuring amplifiers on request

Time-saving plug-and-play sensors ideally suited for industrial environments.

Optionally available with inline - amplifier

  • Industrial standard interfaces available: 0...10 V, 4...20 mA or IO-Link
  • Measurement chain instead of sensor: No need to configure the measuring amplifier
  • Analogue or digital: Coming along as calibrated measurement chains, simplified set-up process
  • Cost effective due to reduced cable costs and simplyfied integration. No space in the cabinet required

Easier integration, less costs and more reliability with the amplifier options.

Filter

close
Language keyboard_arrow_down
C9C; Force Transducer; Data sheet; B03968 Data Sheets English
C9C; Capteur de force; Caractéristiques techniques; B03865 Data Sheets French
C9C; 力センサ; Data sheet; B04943 Data Sheets Japanese
C9C; Kraftaufnehmer; Datenblatt; B03867 Data Sheets German
C9C; Trasduttore di forza; Prospetto dati; B03966 Data Sheets Italian
Quick Start Guide; C9C; A06030 Quick Start Guide English, Italian, French, Chinese, German
C9C; A03729 Mounting Instructions English, Italian, French, German
Release Notes - IO-Link Force Sensors Release Note English

Sales documents

Reliable force measurement - Brochure Brochure English
Force transducers - Brochures Brochure German

Certificates and Approvals

U9C, U9CCV MPZ..., C9C, C9CCV MPZ... - EU Declaration of Conformity Declaration of Conformity English
C9C capacity 50 N - CAD CAD Step Files
C9C capacity 100 N - CAD CAD Step Files
C9C capacity 200 N - CAD CAD Step Files
C9C capacity 0.5 kN - CAD CAD Step Files
C9C capacity 1 kN - CAD CAD Step Files
C9C capacity 2 kN - CAD CAD Step Files
C9C capacity 5 kN - CAD CAD Step Files
C9C capacity 10 kN - CAD CAD Step Files
C9C capacity 20 kN - CAD CAD Step Files
C9C capacity 50 kN - CAD CAD Step Files
Inline Amplifier capacity 50 N ... 50 kN - CAD CAD Step Files
IO1 - firmware v1.2.6 Firmware
C9C 50 N - IODD v1.2.0 IODD-Files (IO-Link)
C9C 100 N - IODD v1.2.0 IODD-Files (IO-Link)
C9C 200 N - IODD v1.2.0 IODD-Files (IO-Link)
C9C 0.5 kN - IODD v1.2.0 IODD-Files (IO-Link)
C9C 1 kN - IODD v1.2.0 IODD-Files (IO-Link)
C9C 2 kN - IODD v1.2.0 IODD-Files (IO-Link)
C9C 5 kN - IODD v1.2.0 IODD-Files (IO-Link)
C9C 10 kN - IODD v1.2.0 IODD-Files (IO-Link)
C9C 20 kN - IODD v1.2.0 IODD-Files (IO-Link)
C9C 50 kN - IODD v1.2.0 IODD-Files (IO-Link)
IO2 - firmware v2.0.0 Firmware
C9C 0.5 kN - IODD v2.0.0 IODD-Files (IO-Link)
C9C 1 kN - IODD v2.0.0 IODD-Files (IO-Link)
C9C 2 kN - IODD v2.0.0 IODD-Files (IO-Link)
C9C 5 kN - IODD v2.0.0 IODD-Files (IO-Link)
C9C 10 kN - IODD v2.0.0 IODD-Files (IO-Link)
C9C 20 kN - IODD v2.0.0 IODD-Files (IO-Link)
C9C 50 kN - IODD v2.0.0 IODD-Files (IO-Link)
IO3 - firmware v2.0.8 Firmware
C9C 100 N - IODD v2.0.8 IODD-Files (IO-Link)
C9C 200 N - IODD v2.0.8 IODD-Files (IO-Link)
C9C 0.5 kN - IODD v2.0.8 IODD-Files (IO-Link)
C9C 1 kN - IODD v2.0.8 IODD-Files (IO-Link)
C9C 2 kN - IODD v2.0.8 IODD-Files (IO-Link)
C9C 5 kN - IODD v2.0.8 IODD-Files (IO-Link)
C9C 10 kN - IODD v2.0.8 IODD-Files (IO-Link)
C9C 20 kN - IODD v2.0.8 IODD-Files (IO-Link)
C9C 50 kN - IODD v2.0.8 IODD-Files (IO-Link)
IO4 - firmware v2.0.10 Firmware
C9C 50 N - IODD v2.0.10 IODD-Files (IO-Link)
C9C 100 N - IODD v2.0.10 IODD-Files (IO-Link)
C9C 200 N - IODD v2.0.10 IODD-Files (IO-Link)
C9C 0.5 kN - IODD v2.0.10 IODD-Files (IO-Link)
C9C 1 kN - IODD v2.0.10 IODD-Files (IO-Link)
C9C 2 kN - IODD v2.0.10 IODD-Files (IO-Link)
C9C 5 kN - IODD v2.0.10 IODD-Files (IO-Link)
C9C 10 kN - IODD v2.0.10 IODD-Files (IO-Link)
C9C 20 kN - IODD v2.0.10 IODD-Files (IO-Link)
C9C 50 kN - IODD v2.0.10 IODD-Files (IO-Link)
IO5 Firmware v2.0.12 Firmware
C9C 50 N - IODD v2.0.12 IODD-Files (IO-Link)
C9C 100 N - IODD v2.0.12 IODD-Files (IO-Link)
C9C 200 N - IODD v2.0.12 IODD-Files (IO-Link)
C9C 0.5 kN - IODD v2.0.12 IODD-Files (IO-Link)
C9C 1 kN - IODD v2.0.12 IODD-Files (IO-Link)
C9C 2 kN - IODD v2.0.12 IODD-Files (IO-Link)
C9C 5 kN - IODD v2.0.12 IODD-Files (IO-Link)
C9C 10 kN - IODD v2.0.12 IODD-Files (IO-Link)
C9C 20 kN - IODD v2.0.12 IODD-Files (IO-Link)
C9C 50 kN - IODD v2.0.12 IODD-Files (IO-Link)
PLC Function Block IOL Force - RSLogix5000 - EN Function Blocks
PLC Function Block IOL Force - RSLogix5000 - DE Function Blocks
PLC Function Block IOL Force - TwinCAT V3 - EN Function Blocks
PLC Function Block IOL Force- TwinCAT V3 - DE Function Blocks
PLC Function Block IOL Force - TIA Portal V14 - EN Function Blocks
PLC Function Block IOL Force - TIA Portal V14 - DE Function Blocks
C9C 50 N - IODD v2.0.0 IODD-Files (IO-Link)
C9C 100 N - IODD v2.0.0 IODD-Files (IO-Link)
C9C 200 N - IODD v2.0.0 IODD-Files (IO-Link)
C9C 50 N - IODD v2.0.8 IODD-Files (IO-Link)
C9C
Maximum capacity (nominal load) 2 kN, 100 N, 1 kN, 10 kN, 20 kN, 50 N, 200 N, 0.5 kN, 5 kN, 50 kN
Maximum capacity (nominal load) 450 lbf, 22.5 lbf, 225 lbf, 2.25 klbf, 4.5 klbf, 11.2 lbf, 45 lbf, 112 lbf, 1.12 klbf, 2.5 klbf, 11.2 klbf, 1.12 lbf
Tensile / compression Compression
Type/technology Strain Gauge
Calibration Calibrated
Output signal mV/V (passive strain gauge), Voltage (0…10V), Current (4-20mA), IO-Link
Degree of protection IP67
Mechanical interfaces Spherical load introduction
Height (without accessories) 13 mm, 15 mm, 28 mm
Height (without accessories) 0.512 in, 0.591 in, 1.1 in
Diameter (without cable or plug) 26 mm, 46 mm
Diameter (without cable or plug) 3.1496 in, 2.972435 in, 1.02362 in, 1.81102 in, 2.066925 in, 2.251964 in