TYPE 4944

1/4" PRESSURE-FIELD MICROPHONE, PREPOLARIZED

Type 4944 is a ¼-inch Prepolarized Pressure-field Microphone designed for high-level and high-frequency measurements over a frequency range of 4 Hz To 70 kHz.

img

TYPE 4944

expand_more
chevron_left
chevron_right

Prepolarized ¼″ Pressure-field Microphone Type 4944 is specially designed for high-level and high-frequency measurements. By using new materials and a new way of mounting the diaphragm, the microphone is geared to withstand rough handling. The assembly of the microphone in a clean room environment ensures that the microphone can be used in high-humidity environments and still produce reliable results. Type 4944 can be used with sound level meters to measure high sound pressure levels

  • High-level measurements
  • High-frequency measurements
  • Flush mounting
  • In small closed couplers, close to hard reflective surfaces or flush-mounted
  • The sensitivity has been optimised to allow measurements of high sound pressure levels without clipping in the built-in CCLD preamplifier.
Idioma keyboard_arrow_down
FAMILY 4944
Standard IEC 61094
Sound field Pressure field
Polarization CCLD
Sensitivity 0.9 mV/Pa
Lower frequency 16 Hz
Higher frequency 70 kHz, 70000 Hz
Lower dynamic range 48 dB
Higher dynamic range 169 dB
Diameter 1/4 inch
Venting Side
Minimum Temperature -20 °C
Maximum Temperature 100 °C
Minimum Temperature -4 °F
Maximum Temperature 212 °F
Output signal (connectivity) Passive

DISEÑO Y SOLIDEZ

La forma de la parte frontal del micrófono garantiza un rendimiento excelente cuando se instala empotrado. El diafragma soldado con láser en la carcasa del micrófono garantiza que la sensibilidad sea resistente a un manejo brusco durante el montaje empotrado.

MICRÓFONO DAT CD

El micrófono se suministra con un mini-CD. Este mini CD contiene todos los datos de calibración individuales, así como correcciones de incidencia aleatoria y Campo libre. También está disponible la corrección correspondiente a la influencia del cono de nariz de ¼ de pulgada UA-0385.

CALIBRACIÓN

La sensibilidad se puede calibrar a 250 Hz utilizando el pistófono Tipo 4228 con el adaptador de ¼ de pulgada DP-0775. La respuesta del campo de presión se puede medir utilizando el actuador UA-0033 con el adaptador DB-0264. La respuesta del campo de presión es igual a la respuesta del actuador.