Linear |
1.5 mm |
0.059 in |
1.2 mm |
0.047 in |
7 mm |
0.276 in |
5 mm |
0.197 in |
Standard (up to 200°C) |
120 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
Linear |
3 mm |
0.118 in |
2.5 mm |
0.098 in |
10.9 mm |
0.429 in |
5.9 mm |
0.232 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
Linear |
6 mm |
0.236 in |
2.7 mm |
0.106 in |
13.9 mm |
0.547 in |
5.9 mm |
0.232 in |
Standard (up to 200°C) |
120 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
Linear |
6 mm |
0.236 in |
2.8 mm |
0.11 in |
13.9 mm |
0.547 in |
5.9 mm |
0.232 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
Linear |
6 mm |
0.236 in |
2.8 mm |
0.11 in |
13.9 mm |
0.547 in |
5.9 mm |
0.232 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
Linear |
10 mm |
0.394 in |
5 mm |
0.197 in |
18 mm |
0.709 in |
8 mm |
0.315 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
Linear |
1.5 mm |
0.059 in |
2 mm |
0.079 in |
6.6 mm |
0.26 in |
4.7 mm |
0.185 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
3-grid rosette |
3 mm |
0.118 in |
1.2 mm |
0.047 in |
9.7 mm |
0.382 in |
14.6 mm |
0.575 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
3-grid rosette |
6 mm |
0.236 in |
2.8 mm |
0.11 in |
13.1 mm |
0.516 in |
22.9 mm |
0.902 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
T rosette |
6 mm |
0.236 in |
6.5 mm |
0.256 in |
12 mm |
0.472 in |
18 mm |
0.709 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
Shear/torsion |
6 mm |
0.236 in |
6 mm |
0.236 in |
16 mm |
0.63 in |
12.2 mm |
0.48 in |
Standard (up to 200°C) |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F) |
Pre-wired (TPE-insulated ribbon cable) |
|
|
Double linear |
1.5 mm, 3 mm, 6 mm |
0.059 in, 0.118 in, 0.236 in |
1.8 mm, 2.7 mm, 3.2 mm |
0.071 in, 0.106 in, 0.126 in |
5.5 mm, 8.2 mm, 10.7 mm |
0.216 in, 0.323 in, 0.421 in |
6 mm, 8 mm, 9 mm |
0.236 in, 0.315 in, 0.354 in |
Limited temperature range |
350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F), Aluminium (23 ppm/K; 12.8 ppm/°F), Austenitic steel (16 ppm/K; 8.9 ppm/°F), Silica / composite (0,5 ppm/K; 0.3 ppm/°F), Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F), Plastic (65 ppm/K; 36.1 ppm/°F), Molybdenum (5.4 ppm/K; 3.0 ppm/°F) |
Fluoropolymer-insulated connection wires, Pre-wired (TPE-insulated ribbon cable) |
|
|
Linear |
0.6 mm, 1.5 mm, 3 mm, 6 mm, 10 mm, 20 mm, 50 mm, 100 mm |
0.024 in, 0.059 in, 0.118 in, 0.236 in, 0.394 in, 0.787 in, 1.969 in, 3.937 in |
1.1 mm, 1.2 mm, 2.7 mm, 5 mm, 0.5 mm, 0.8 mm, 1 mm, 1.2 mm, 2.3 mm, 2.5 mm, 2.8 mm, 4.1 mm, 4.2 mm |
0.043 in, 0.047 in, 0.106 in, 0.197 in, 0.02 in, 0.031 in, 0.039 in, 0.047 in, 0.09 in, 0.098 in, 0.11 in, 0.161 in, 0.165 in |
6 mm, 7 mm, 8 mm, 13.9 mm, 18 mm, 31.8 mm, 63.6 mm, 114.8 mm, 165.6 mm, 9.2 mm, 10.9 mm |
0.236 in, 0.275 in, 0.315 in, 0.547 in, 0.709 in, 1.252 in, 2.504 in, 4.52 in, 6.52 in, 0.362 in, 0.429 in |
4 mm, 5 mm, 5.9 mm, 8 mm, 8.2 mm |
0.157 in, 0.197 in, 0.232 in, 0.315 in, 0.323 in |
Limited temperature range |
120 Ohms, 350 Ohms, 1000 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F), Aluminium (23 ppm/K; 12.8 ppm/°F), Austenitic steel (16 ppm/K; 8.9 ppm/°F), Silica / composite (0,5 ppm/K; 0.3 ppm/°F), Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F), Plastic (65 ppm/K; 36.1 ppm/°F), Molybdenum (5.4 ppm/K; 3.0 ppm/°F) |
Fluoropolymer-insulated connection wires, Pre-wired (TPE-insulated ribbon cable) |
|
|
Linear |
1.5 mm, 3 mm, 6 mm |
0.059 in, 0.118 in, 0.236 in |
2 mm, 4 mm |
0.079 in, 0.157 in |
6.6 mm, 6.3 mm, 9.5 mm, 7 mm |
0.26 in, 0.248 in, 0.374 in, 0.275 in |
4.7 mm, 7 mm, 9.5 mm, 6.3 mm |
0.185 in, 0.276 in, 0.374 in, 0.248 in |
Limited temperature range |
120 Ohms, 350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F), Aluminium (23 ppm/K; 12.8 ppm/°F), Austenitic steel (16 ppm/K; 8.9 ppm/°F), Silica / composite (0,5 ppm/K; 0.3 ppm/°F), Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F), Plastic (65 ppm/K; 36.1 ppm/°F), Molybdenum (5.4 ppm/K; 3.0 ppm/°F) |
Fluoropolymer-insulated connection wires, Pre-wired (TPE-insulated ribbon cable) |
|
|
3-grid rosette |
0.6 mm, 1.5 mm, 3 mm, 6 mm |
0.024 in, 0.059 in, 0.118 in, 0.236 in |
1.1 mm, 1.2 mm, 3 mm, 1.6 mm, 2.8 mm |
0.043 in, 0.047 in, 0.118 in, 0.063 in, 0.11 in |
4.8 mm, 8.2 mm, 9.7 mm, 13 mm, 13.1 mm |
0.189 in, 0.323 in, 0.382 in, 0.512 in, 0.515 in |
8.7 mm, 14.6 mm, 22.9 mm |
0.342 in, 0.575 in, 0.902 in |
Limited temperature range |
120 Ohms, 350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F), Aluminium (23 ppm/K; 12.8 ppm/°F), Austenitic steel (16 ppm/K; 8.9 ppm/°F), Silica / composite (0,5 ppm/K; 0.3 ppm/°F), Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F), Plastic (65 ppm/K; 36.1 ppm/°F), Molybdenum (5.4 ppm/K; 3.0 ppm/°F) |
Fluoropolymer-insulated connection wires, Pre-wired (TPE-insulated ribbon cable) |
|
|
T rosette |
0.6 mm, 1.5 mm, 3 mm, 6 mm |
0.024 in, 0.059 in, 0.118 in, 0.236 in |
1 mm, 1.6 mm, 3.2 mm, 6.3 mm, 1.7 mm, 3.3 mm, 6.5 mm |
0.039 in, 0.063 in, 0.126 in, 0.248 in, 0.067 in, 0.13 in, 0.256 in |
6 mm, 6.3 mm, 8 mm, 12 mm, 7.6 mm |
0.236 in, 0.248 in, 0.315 in, 0.472 in, 0.299 in |
7 mm, 8 mm, 10.5 mm, 17.5 mm, 7.7 mm, 10.9 mm, 18 mm |
0.276 in, 0.315 in, 0.413 in, 0.689 in, 0.303 in, 0.429 in, 0.709 in |
Limited temperature range |
120 Ohms, 350 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F), Aluminium (23 ppm/K; 12.8 ppm/°F), Austenitic steel (16 ppm/K; 8.9 ppm/°F), Silica / composite (0,5 ppm/K; 0.3 ppm/°F), Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F), Plastic (65 ppm/K; 36.1 ppm/°F), Molybdenum (5.4 ppm/K; 3.0 ppm/°F) |
Fluoropolymer-insulated connection wires, Pre-wired (TPE-insulated ribbon cable) |
|
|
T rosette |
3 mm, 6 mm |
0.118 in, 0.236 in |
3 mm, 6 mm, 5.2 mm, 6.1 mm |
0.118 in, 0.236 in, 0.204 in, 0.24 in |
11 mm, 16 mm |
0.433 in, 0.63 in |
8 mm, 12.2 mm |
0.315 in, 0.48 in |
Limited temperature range |
120 Ohms, 350 Ohms, 700 Ohms |
Ferritic steel (10.8 ppm/K; 6.0 ppm/°F), Aluminium (23 ppm/K; 12.8 ppm/°F), Austenitic steel (16 ppm/K; 8.9 ppm/°F), Silica / composite (0,5 ppm/K; 0.3 ppm/°F), Titanium / gray cast iron (9 ppm/K; 5.0 ppm/°F), Plastic (65 ppm/K; 36.1 ppm/°F), Molybdenum (5.4 ppm/K; 3.0 ppm/°F) |
Fluoropolymer-insulated connection wires, Pre-wired (TPE-insulated ribbon cable) |