U10M Tensile-Compressive Force Transducer: Capacities from 1.25 kN to 2.5 MN

The rotationally symmetric, low-profile U10 force is oustanding precise and made from rustfree materials. U10M load cells are suitable for acquiring fast, dynamic force trends and static forces. HBK offers a wide range of options (Double bridges, TEDS, mechanical adaptations, integrated amplifiers,...) so that a U10 can be adapted to its measurment task.

  • HBK accuracy class:  0.02 ... 0.05
  • Capacities: 1.25 kN ... 2.5 MN
  • Output signals: mV/V (passive, Wheatstone Bridge) and IO-Link

 

New: With the new option "VAIO", the U10M comes along with an integrated digital amplifier. Your advantages:

  • Greater precission: Linearity error 0.005 % for capacities up to 250 kN, higher capacities improved to 0.03 %. TC0: 0.006 %/ 10 K.
  • Improved reliability: The Sensor Health monitoring of the U10M sends warnings in case of exceeding temperature or mechanical limits before problems occur.
  • More information: Temperature measurement, statistical information.
  • Lower costs, easy setup: The U10M with the VAIO option comes along as adjusted sensor: No more complicated or time consuming setups. When connected to an IO-Link master, you will get precise readings in Newton immediately. 
  • Many built in features: Limit switches, peak detection, digital output, filter.
  • Fast: Internal sampling rate: 40 kHz, 1 ms cycling time to the IO-Link master.

 Please have a look at the K-U10M model. Beside many other options, you can find order information for the IO-Link version as well.

 

Advantages of all U10M:

Precise

  • Benchmark precision.
  • TC0 of 150 ppm/ 10 K or 75 ppm/ 10 K with 200 % calibration. With integrated amplifier: 75 ppm/ 10 K or 60 ppm/ 10 K with 200 % calibration.
  • Minimal linearity deviation and hysteresis and very good repeatability. 
  • With integrated instrument: Linearity deviation at the physical limit.

Large measuring range in compliance with specified accuracy requirements, improved yield in product tests through small error bands. Even lower measurment uncertainty with build-in amplfiers.

Robust

  • Made from rust-proof materials, degree of protection IP68 (with cable option).
  • Electrical bending moment compensation: Bending (for example resulting from applied lateral forces) does not impact the measurement result.
  • Fit for fatigue tests, peak to peak load of 200 % of nominal force can be applied.
  • Vibration resistant.
  • EMC approved.
  • With IO-LNK: Sensor Health monitoring warns in case of exceeding mechanical or thermal limits. 

Reliability even in unfavorable measurement conditions (e.g. temperature gradients, parasitic mechanical influences). Improved reliability with built-in amplifier.

Adaptable to your needs and cost effective 

  • U10M optimally adapts to its measurement task: Over 15,000 combinations are available.
  • Select from many options such as TEDS, flange or foot adapter version, 100 % or 200 % calibration, load introduction pin, several connectors and cable options and more.

Time saving with plug-and-play solutions, easy adaption, cost-effective amplifier versions. 

Filter

close
Language keyboard_arrow_down
U10M - Data Sheet Data Sheets English
U10M - Data Sheets Data Sheets French
U10M - Data Sheets Data Sheets German
SCOUT55 - Data Sheets Data Sheets Italian
U10M - Data Sheets Data Sheets Japanese
U10M - Data Sheets Data Sheets Chinese
U10M - Quick Start Guide Quick Start Guide English, Italian, French, Chinese, German
U10M - Mounting Instructions Mounting Instructions English, Italian, French, Chinese, German
Release Notes - IO-Link Force Sensors Release Note English

Sales documents

Reliable force measurement - Brochure Brochure English
Force transducers - Brochures Brochure German

Certificates and Approvals

U10M, U10S, U10F,U15, C10, C15 - EU Declaration of Conformity Declaration of Conformity English
U10M capacity 1.25 kN Flange - CAD CAD Step Files
U10M capacity 2.5 kN Flange - CAD CAD Step Files
U10M capacity 5 kN Flange - CAD CAD Step Files
U10M capacity 12.5 kN Flange - CAD CAD Step Files
U10M capacity 25 kN Flange - CAD CAD Step Files
U10M capacity 50 kN Flange - CAD CAD Step Files
U10M capacity 125 kN Flange - CAD CAD Step Files
U10M capacity 250 kN Flange - CAD CAD Step Files
U10M capacity 500 kN Flange - CAD CAD Step Files
U10M capacity 1.25 MN Flange - CAD CAD Step Files
U10M Capacity 1.25 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 2.5 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 5 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 12.5 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 25 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 50 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 125 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 250 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 500 kN Flange with integrated amplifier - CAD CAD Step Files
U10M Capacity 1.25 MN Flange with integrated amplifier - CAD CAD Step Files
U10M capacity 1.25 kN with load base - CAD CAD Step Files
U10M capacity 2.5 kN with load base - CAD CAD Step Files
U10M capacity 5 kN with load base - CAD CAD Step Files
U10M capacity 12.5 kN with load base - CAD CAD Step Files
U10M capacity 25 kN with load base - CAD CAD Step Files
U10M capacity 50 kN with load base - CAD CAD Step Files
U10M capacity 125 kN with load base - CAD CAD Step Files
U10M capacity 250 kN with load base - CAD CAD Step Files
U10M capacity 500 kN with load base - CAD CAD Step Files
U10M capacity 1.25 MN with load base - CAD CAD Step Files
U10M Capacity 1.25 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 2.5 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 5 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 12.5 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 25 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 50 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 125 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 250 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 500 kN with load base and integrated amplifier -  CAD CAD Step Files
U10M Capacity 1.25 MN with load base and integrated amplifier -  CAD CAD Step Files
IO3 - firmware v2.0.8 Firmware
U10M 1.25 kN - IODD v2.0.8 IODD files (IO Link)
U10M 2.5 kN - IODD v2.0.8 IODD files (IO Link)
U10M 5 kN - IODD v2.0.8 IODD files (IO Link)
U10M 12.5 kN - IODD v2.0.8 IODD files (IO Link)
U10M 25 kN - IODD v2.0.8 IODD files (IO Link)
U10M 50 kN - IODD v2.0.8 IODD files (IO Link)
U10M 125 kN - IODD v2.0.8 IODD files (IO Link)
U10M 250 kN - IODD v2.0.8 IODD files (IO Link)
U10M 500 kN - IODD v2.0.8 IODD files (IO Link)
U10M 1.25 MN - IODD v2.0.8 IODD files (IO Link)
IO4 - firmware v2.0.10 Firmware
U10M 1.25 kN - IODD v2.0.10 IODD files (IO Link)
U10M 2.5 kN - IODD v2.0.10 IODD files (IO Link)
U10M 5 kN - IODD v2.0.10 IODD files (IO Link)
U10M 12.5 kN - IODD v2.0.10 IODD files (IO Link)
U10M 25 kN - IODD v2.0.10 IODD files (IO Link)
U10M 50 kN - IODD v2.0.10 IODD files (IO Link)
U10M 125 kN - IODD v2.0.10 IODD files (IO Link)
U10M 250 kN - IODD v2.0.10 IODD files (IO Link)
U10M 500kN - IODD v2.0.10 IODD files (IO Link)
U10M 1.25 MN - IODD v2.0.10 IODD files (IO Link)
IO5 Firmware v2.0.12 Firmware
U10M 1.25 kN - IODD v2.0.12 IODD files (IO Link)
U10M 2.5 kN - IODD v2.0.12 IODD files (IO Link)
U10M 5 kN - IODD v2.0.12 IODD files (IO Link)
U10M 12.5 kN - IODD v2.0.12 IODD files (IO Link)
U10M 25 kN - IODD v2.0.12 IODD files (IO Link)
U10M 50 kN - IODD v2.0.12 IODD files (IO Link)
U10M 125 kN - IODD v2.0.12 IODD files (IO Link)
U10M 250 kN - IODD v2.0.12 IODD files (IO Link)
U10M 500 kN - IODD v2.0.12 IODD files (IO Link)
U10M 1.25 MN - IODD v2.0.12 IODD files (IO Link)
PLC Function Block IOL Force - RSLogix5000 - EN PLC Function blocks
PLC Function Block IOL Force - RSLogix5000 - DE PLC Function blocks
PLC Function Block IOL Force - TwinCAT V3 - EN PLC Function blocks
PLC Function Block IOL Force- TwinCAT V3 - DE PLC Function blocks
PLC Function Block IOL Force - TIA Portal V14 - EN PLC Function blocks
PLC Function Block IOL Force - TIA Portal V14 - DE PLC Function blocks
U10M
Maximum capacity (nominal load) 12.5 kN, 5 kN, 1.25 kN, 2.5 kN, 25 kN, 50 kN, 125 kN, 250 kN, 500 kN, 1.25 MN
Maximum capacity (nominal load) 2.81 klbf, 1.12 klbf, 281 lbf, 562 lbf, 5.62 klbf, 11.2 klbf, 28.1 klbf, 56.2 klbf, 281 klbf, 112 klbf
Tensile / compression Both directions
Type/technology Strain Gauge
Calibration Calibrated
Output signal mV/V (passive strain gauge), IO-Link
HBK Accuracy class 0.03, 0.02, 0.04, 0.05
Degree of protection IP67
Mechanical adaptation Central thread
Height (without accessories) 34.9 mm, 44.5 mm, 63.5 mm, 88.9 mm, 127 mm
Height (without accessories) 1.37 in, 1.75 in, 2.5 in, 3.5 in, 5.08 in
Diameter (without cable or plug) 104.8 mm, 390 mm, 153.9 mm, 203.2 mm, 279 mm
Diameter (without cable or plug) 4.125976 in, 15.3543 in, 6.059043 in, 7.999984 in, 10.98423 in

자주 묻는 질문 | HBK IO-Link 스마트 힘 센서에 관한 질문과 답변

네. 차세대 힘 측정 도구에 대해서도 HBK는 기존 제품과 동일한 교정 서비스를 제공하여 측정값의 추적 가능성을 보장합니다. ISO 9001과 같은 품질 기준의 요구사항은 제한 없이 충족될 수 있습니다.

HBK 교정 실험실은 ISO 17025 표준에 따라 인증을 받았습니다. 이는 HBK의 교정 서비스가 국가 표준에 대한 추적성 요구사항을 모두 충족함을 의미하며, 이는 ISO 9001과 같은 품질 표준의 핵심 요구사항입니다. 디지털 센서의 교정 과정은 기존 로드셀과 동일합니다: 동일한 교정 장비와 표준이 사용됩니다. 결과적으로 고객은 HBK의 디지털 센서 교정 장비의 높은 정확도로 혜택을 받습니다.

교정 절차는 다음과 같습니다:

a. 첫 번째 단계는 센서에 저장된 선형화(지원점 또는 3차 다항식의 계수)를 위한 모든 데이터를 읽어내는 것입니다. 이 데이터는 안전하게 외부 저장소에 보관됩니다.
b. 이후 모든 선형화 데이터가 삭제됩니다. 센서는 이제 선형성 오차 보정 없이 작동합니다.
c. 센서에 서로 다른 부하 단계가 적용되며, 그 결과는 센서 메모리에 저장됩니다. 센서가 이제 선형성 보정 기능으로 작동합니다.

결과적으로, 선형화 오차에 대한 능동 보상이 적용된 플러그 앤 플레이 센서를 제공받게 됩니다. 측정 불확도 계산은 전체 시스템에 대해 유효합니다.

작업 표준 교정 서비스도 이용 가능합니다.

비용 절감, 간편하고 빠른 설정, 현장 수준까지의 원활한 소통 – 이점들은 상당합니다.

대부분의 경우, 비용 절감은 IO-Link 기술을 탑재한 센서를 선택하는 가장 강력한 근거입니다. IO-Link 기술의 가장 중요한 이점은 다음과 같습니다:

  1. 캐비닛 내부에 공간이 필요하지 않습니다.
  2. 케이블링 비용 절감.
  3. 통합 과정에서의 시간 절감.
  4. 매개변수 설정 없이 플러그 앤 플레이: 장치를 IO-Link 마스터에 연결하면 즉시 정확한 측정값을 뉴턴 단위로 확인할 수 있습니다.
  5. 제어 레벨에서 현장 레벨로의 통신이 가능합니다.