arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

arrow_back_ios

Main Menu

ClipX

This precise one-channel signal conditioner offers all modern automation interfaces, an intuitive web interface and smart functions.

img

ClipX

expand_more
chevron_left
chevron_right

With an accuracy class of 0.01 and an integrated calibration certificate, the interference-proof signal conditioner ClipX is setting new standards in industrial process control. ClipX adapts to your measurement task, regardless of whether it is used with single- or multiple-channel applications, in manufacturing machines, in test benches or for production monitoring. Owing to the Plug and Play principle, up to six devices can be plugged simultaneously in a modular setup and the measured data can be pre-calculated. Unlike conventional measuring signal conditioners, ClipX does not require a separate head module for direct data processing.

ClipX provides all the latest automation interfaces to perfectly integrate the device into comprehensive control concepts. A particular feature is the intuitive web interface that also enables remote operation, parameterization, and diagnosis.

  • Accuracy class: 0.01
  • Measurement inputs: Full-bridge and half-bridge strain gauges, piezoresistive transducer, potentiometer, Pt100, current, and voltage
  • Interfaces: PROFINET, EtherCAT®,PROFIBUS, Ethernet/IP™*, Modbus-TCP, analog (V/mA,) digital-I/O, and Ethernet (TCP/IP)
  • IIoT (Industrial Internet of Things): Remote diagnosis, health monitoring and web integration; integrated OPC-UA server 

Precise and interference-proof

  • Fast and digital signal conditioning for force sensors, load cells, torque sensors, pressure transducers, as well as temperature and standardized signals (current/voltage)
  • Guaranteed measurement accuracy, even in harsh industrial environments with electrical interferences
  • Full traceability owing to EN10204-compliant calibration records that are directly stored in the device
  • In combination with the SD01A Zener barrier , sensors can also be operated as intrinsically safe devices in potentially explosive atmospheres, measurement circuit type (Ex II (1) GD, [EEx ia]IIC).

Reliable results and trustworthy acquisition of mechanical and electrical quantities in industrial environments

Faster industrial processes

  • A high sample rate and high bandwidth facilitate for easy use in automation environments
  • Quick setup and diagnosis using the display on the device and the intuitive web interface
  • Full support of TEDS (Transducer Electronic Data Sheet) 
  • ClipX-bus allows transmission and computation of measured values between up to 6 devices
  • Interfaces: PROFINET, EtherCAT®, PROFIBUS, Ethernet/IP™, Modbus-TCP, analog (V/mA,) digital-I/O, Ethernet (TCP/IP)
  • Integrated OPC-UA server 

Easy setup with integrated web interface, time- and cost-saving remote diagnosis, and automated channel parameterization of the measurement chain (TEDS) or the integrated Adjustment Assistant that guides the user step by step 

Efficient and profitable

  • Individual system setup and compact design
  • Easy and safe assembly without tools
  • Transmission of measured values in millisecond intervals using the ClipX-bus 
  • Mathematical and technological calculation channels (Smart Functions) allow signal conditioning/analysis and easy parameterization
  • Individually configurable input/output signals and fieldbus interfaces
  • All the device settings can be individually configured via the Ethernet and fieldbus interfaces and the internal object directory
  • Open to integration with many other software programs: LabVIEW, Visual Studio .NET under Windows as well as Linux

Unbeatable price-to-performance ratio and a future-proof investment because of the open automation standards

Language keyboard_arrow_down
ClipX - Data Sheet Data Sheets English
ClipX - Data Sheets Data Sheets Russian
ClipX - Data Sheets Data Sheets Korean
ClipX - Data Sheets Data Sheets Japanese
ClipX - Data Sheets Data Sheets Chinese
ClipX - Data Sheets Data Sheets German
ClipX - Data Sheets Data Sheets Italian
ClipX - Data Sheets Data Sheets French
ClipX - Data Sheets Data Sheets Portuguese
ClipX - Data Sheets Data Sheets Spanish
ClipX - Quick Start Guide Quick Start Guide English, Italian, French, Chinese, German
ClipX - Operating Manual Manual English, German
ClipX Software & Driver - Operating Manual Manual English, German
ClipX - Ethercat example Tech Notes English
ClipX - Ethernet ip example Tech Notes English
ClipX - Modbus TCP example Tech Notes English, German
ClipX - Profibus example Tech Notes English
ClipX - Profinet example Tech Notes English
ClipX - TechNote: With Allen Bradley PLC EN Tech Notes English
ClipX - TechNote: Acceleration sensor EN Tech Notes English
ClipX - TechNote: Dynamic weighing EN Tech Notes English
ClipX - TechNote: Event counter EN Tech Notes English
ClipX - TechNote: IEPE sensor EN Tech Notes English
ClipX - TechNote: Mechanical work EN Tech Notes English
ClipX - TechNote: TB21 measuring screw EN Tech Notes English
ClipX - TechNote: Peak value monitoring EN Tech Notes English
ClipX - TechNote: Piezoelectric sensor EN Tech Notes English
ClipX - TechNote: Tolerance window EN Tech Notes English
ClipX - TechNote: Peak-to-peak time EN Tech Notes English
ClipX - TechNote: PID controller EN Tech Notes English
ClipX - TechNote: Adjustment assistant EN Tech Notes English
PMX & ClipX - For several PLC formats Tech Notes English, German
ClipX - TechNote: With Allen Bradley PLC DE Tech Notes German
ClipX - TechNote: Acceleration sensor DE Tech Notes German
ClipX - TechNote: Dynamic weighing DE Tech Notes German
ClipX - TechNote: Event counter DE Tech Notes German
ClipX - TechNote: IEPE sensor DE Tech Notes German
ClipX - TechNote: Mechanical work DE Tech Notes German
ClipX - TechNote: TB21 measuring screw DE Tech Notes German
ClipX - TechNote: Piezoelectric sensor DE Tech Notes German
ClipX - TechNote: PID controller DE Tech Notes German
ClipX - TechNote: Adjustment assistant DE Tech Notes German

Sales documents

ClipX - Brochure Brochure English
ClipX - Brochures Brochure Japanese
ClipX - Brochures Brochure French
ClipX - Brochures Brochure Korean
ClipX - Brochures Brochure Portuguese
ClipX - Brochures Brochure Spanish
ClipX - Brochures Brochure Italian
ClipX - Brochures Brochure German
ClipX - Brochures Brochure Chinese

Certificates and Approvals

ClipX - ProfiNet-Certificate Certificates English
ClipX - Ethernet/IP - ODVA Certificate Certificates English
ClipX BM40/BM40PB/BM40IE - EU Declaration of Conformity Declaration of Conformity English
ClipX
Number of inputs Single channel
Input Strain gauge full/half bridge, Electrical voltage, Electrical current, Resistance
Interface Analog, Digital IO, TCP/IP, EtherCAT, ProfiNet, Modbus/TCP, Ethernet/IP, ProfiBus
Accuracy class 0.01
Sample rate 19200 S/s
Housing DIN rail
Internal logic Calculated channel
Legal for trade No

유연한 측정 아키텍처를 위한 개방형 산업 인터페이스

Parallel IT/OT connectivity. A connection chart

테스트, 기계 및 생산을 위한 유연한 신호 처리

무료 백서 다운로드

신호 처리 시 3가지 오류 방지하여 정확한 시험 결과 도출하기

  • 산업용 신호 컨디셔너의 정확도에 부정적인 영향을 미칠 수 있는 요인은 무엇인가요?
  • 정확도는 측정 결과에 어떤 영향을 미치나요?
  • 정밀 측정 체인을 어떻게 설정할 수 있나요?

단일 공급업체의 디지털 및 아날로그 측정 체인

HBM은 완벽하게 조화된 센서와 측정 모듈을 개발 및 생산하며, 이들을 결합하면 시스템 불연속성 없이 정밀하고 신뢰할 수 있는 측정 결과를 제공합니다. ISO9001, ISO14001 인증 및 공인된 HBM 교정 실험실(DAkkS)은 측정 체인의 품질이 ISO 17025에 따라 추적 가능함을 보장합니다.

ClipX 모듈용 교정 증명서를 여기서 다운로드하세요. 모든 측정 체인은 최첨단 디지털 및 아날로그 자동화 인터페이스 덕분에 전체 제어 시스템에 손쉽게 통합될 수 있다는 것은 말할 필요도 없습니다.

직관적인 웹 인터페이스

ClipX는 혁신적이고 직관적인 웹 인터페이스를 제공하며, 별도의 소프트웨어 설치나 교육 없이 즉시 사용 가능합니다.

  • 모든 브라우저 기반 기기(모바일 기기도 포함)에서 사용할 수 있습니다.
  • 터치스크린 제어 및 3단계 사용자 관리
  • 회사 네트워크 또는 인터넷을 통한 원격 유지보수 
  • 웹 인터페이스는 WiFi 라우터를 사용하여 모바일 기기에서 사용할 수 있습니다.
  • 나만의 맞춤형 디스플레이 페이지를 생성하세요
  • 통합 도움말 및 조정 도우미가 포함된 다국어 사용자 인터페이스

개별 시스템 설정

ClipX는 개별 측정 체인과 시스템 모두를 밀리초 단위로 동기화할 수 있으며, 선택적으로 PC 또는 필드버스 연결을 동시에 수행할 수 있습니다.

  • 측정값과 그 상태(진단)는 ClipX 버스를 통해 전송됩니다
  • 헤드 모듈이 필요하지 않아 비용을 절감합니다.
  • 합산, 피크값 또는 제어와 같은 모든 신호의 직접 처리
  • 다중 클라이언트 기능은 모든 인터페이스를 병렬 및 실시간으로 사용할 수 있게 합니다.
  • 디지털 입력 및 출력은 빠른 제어 및 모니터링 작업(예: 경보)을 수행할 수 있습니다.

튜토리얼 비디오: ClipX 설정하기

이 단계별 튜토리얼 동영상을 시청하고 ClipX 설정이 얼마나 쉬운지 확인해 보세요!

  • 장치 설정에 별도의 도구가 필요하지 않습니다.
  • 플러그 앤 플레이 원리
  • 직관적인 웹 인터페이스에 즉시 접근

무료 백서 다운로드

측정 기술 4.0 - 생산 공정 최적화

  • 현대식 신호 컨디셔너는 어떻게 생산 공정을 최적화하여 더 높은 생산량을 달성할 수 있나요?

지금 다운로드

산업용 사물인터넷(IIoT)

ClipX는 이미 미래 산업용 사물인터넷(IIoT)의 요구 사항을 충족합니다.

  • TEDS 또는 스마트 조정 어시스턴트를 통한 간편한 증폭기 매개변수 설정
  • 스마트 기능(진단 및 분석)을 통한 스마트 기기
  • PLC, 시스템 PC 및 서비스 인터페이스의 상호작용 없는 병렬 작동
  • 유연한 자동화 인터페이스와 클라우드 데이터 로깅(요청 시 OPC-UA 프로토콜 지원)을 통한 높은 전향적 호환성과 투자 안전성

관련 콘텐츠