See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Test Solutions See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Articles See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

CST

The CST/300 piezoelectric strain sensor precisely measures minimal strain ranging from a few µm/m up to its nominal strain of 300 µm/m, which is ideal for indirect force measurement, for instance, in the monitoring of press and welding processes.

img

CST

expand_more
chevron_left
chevron_right

CST/300 Strain Transducer: A Sensitive Sensor with a Large Measuring Range

The CST/300 piezoelectric strain transducer precisely measures the strain in a very broad measuring range up to 300 µm/m. Owing to its exceptionally high sensitivity, it is suitable for applications with a very low strain level, for instance, for indirect force measurement in presses and welding systems in the industry or for crimping in cable production.

The CST/300 is mounted on the structure that is to be monitored with a single screw; no drilling template or similar tools are required. The strain transducer measures the strain resulting from the application of a force to the target object and converts it into a charge signal. A calibration enables the active force to be correlated with the transducer’s output signal, at a high measurement quality, even in components designed with a high stiffness and low strain level.

Electrical isolation allows the direct mounting of the charge amplifiers and summing boxes from HBM that perfectly match the CST/300; no insulating washers are required.

Due to its compact dimensions, the CST/300 can be ideally used in applications where little space is available It is suitable for many industrial applications, owing to its robust measuring body, IP65 degree of protection, and insensitivity to acceleration. Besides the piezoelectric strain transducers, HBK also offers strain transducers based on strain gauges as well as a wide range of strain gauges that meet the many different requirements required in strain measurement for indirect force measurement.

  • HBM accuracy class: 2
  • Nominal strain: 300 µm/m
  • Dimensions: 46 mm x 17 mm x 12 mm

Easy installation where little space is available

  • Force shunt measurement where little space is available
  • Very compact, with dimensions of only 46 mm x 17 mm x 12 mm
  • Easy and reliable installation with a single screw

For demanding measurements that require a compact design and a broad measuring range

Wide measuring range and high sensitivity

  • High resolution even with the smallest signals
  • Precise measurement of minimal strain due to high sensitivity
  • High-quality results owing to low-drift design
  • Noise-free data transmission because of a high-grade, fixed coaxial cable

Precise strain measurement even in very stiff structures because of a high sensitivity

Extensive accessories for industrial applications

  • Robust measuring body made from stainless steel materials
  • Long-term resistance in industrial environments due to the IP65 degree of protection
  • Insensitive to fast acceleration due to its high-impact resistance
  • Matching and electrically-isolated amplifiers and summing boxes available

Suitable for industrial environments due to a high impact resistance and the IP65 degree of protection

File

Description

Type

Languages

Size

CST/300 - Data Sheet (B03873)

CST/300 - Data Sheet

Technical Document English 51 KB
CST/300 - Mounting instructions (A03871)

CST300 - Mounting Instructions

Technical Document English, Italian, French, German 310 KB
CFT/CFT+/CFW/CLP/CSW/CST/CHW - EU Declaration of Conformity (ce300)

CFT/CFT+/CFW/CLP/CSW/CST/CHW - EU Declaration of Conformity

Certificate English 1 MB