arrow_back_ios

Main Menu

See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All Industrial electronics See All S&V Signal conditioner See All DAQ Systems See All Power Analyser See All S&V Hand-held devices See All High Precision and Calibration Systems See All Test Solutions See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Vibration Controllers See All Power Amplifiers See All Accessories for Vibration Testing Equipment See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All QuantumX See All LAN-XI See All SomatXR See All MGCplus See All CANHEAD See All Optical Interrogators See All GenHS See All API See All Accessories for acoustic transducers See All Acoustic Calibrators See All Microphone Cartridges See All Microphone Pre-amplifiers See All Microphone Sets See All Sound Sources See All Special Microphones See All Experimental testing See All Transducer Manufacturing (OEM) See All Rotating See All Non-rotating (calibration) See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Type 2270-S

Sound intensity system for noise source location, sound power calculations and noise mapping using a two-channel sound level meter. The system includes Type 2270-S, our two-channel sound level meter, and a two-channel sound intensity probe with the required software.

Code Name
-2270-G-S- SLM 2270 Sound Intensity Analyzer Kit
-2270-S-C- SLM 2270,2 channel, FA, TA & NM w.4231
-2270-G-SC- SLM 2270 Sound Intensity Anal.Kit w.4297

This sound intensity device / intensity system delivers a two-channel sound level meter, a sound intensity device probe, and post-processing software, making it easy for one person to perform a sound intensity measurement from beginning to end.

The system works seemlessly with our Sound Intensity Software Type BZ-7233, and fulfils all relevant IEC standards, enabling measurements that meet ISO, ANSI and ECMA standards.

USE SCENARIOS

  • Sound power characterization and sound source mapping on industrial goods such as industrial pumps and ventilation units
  • Building acoustics evaluations, such as flanking transmission path investigations
  • Sound intensity mapping of electroacoustic devices and consumer products such as loudspeaker cabinets
  • Measuring in situ sound emissions of products in inaccessible places, such as rooftop extractor fans
  • Measurements for noise labelling of products for EU machine directives

The two-channel microphone probe can pinpoint noise sources or to give an average for the surface by scanning each surface of the test object. Automatic measurement guidance and aural feedback during measurements allow you to concentrate on making a smooth scan of the area under investigation. Clear measurement quality indicators confirm your data validity, giving results you can use on the spot.

To help make sense of the measurements later, after exporting data to a PC, you can make notes using text input, voice comments, and photos of the measurement object – using the sound level meter’s camera. A number map showing the source strength can be superimposed on a photo of the object being measured, showing sound intensity contours.

SYSTEM FEATURES

  • Portable and battery powered for in-field measuring projects
  • 1/n-octave analysis
  • Visual data manager keeps track of measurements and data
  • Export data to mapping software
  • Sound intensity measurements to IEC 61043
  • Sound power determination compliant with ISO 9614–1, ISO 9614–2, ANSI S12.12, ECMA 160
  • Sound intensity probe can use either ¼” or ½” microphones 
  • Includes software for archiving, reporting and exporting results
  • Generator output for transmission loss measurements
  • A unique phase-calibration technique lets you make all your measurements with a 12 mm spacer between the two microphones, covering 50 Hz to 10 kHz.

 

COMPLETE KIT

In addition, the Sound Intensity system includes:

  • Weatherproof carrying case (for the hand-held analyzer)
  • Probe with a windscreen
  • Extension stem with a handle
  • Intensity adaptor (for Sound Calibrator Type 4231)
  • Measuring tape
  • Earphones

The case is designed to house optional accessories such as a sound calibrator, sound intensity calibrator and spare batteries.