See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Test Solutions See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All Accessories for Vibration Testing Equipment See All Power Amplifiers See All LDS Shaker Systems See All Vibration Controllers See All Training Courses See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Dynamic Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

3160-A-022-R

2/2-ch Module LAN-XI 51.2kHz

2 ch Input + 2 ch Output Module LAN-XI, designed for applications where system excitation is required, such as audio and electro-acoustic test applications.

img

2/2-ch Module LAN-XI 51.2kHz

expand_more
chevron_left
chevron_right

TYPE 3160, GENERATOR MODULE:

A combination of inputs and generator outputs make a complete stand-alone analyzer test system. The module is ideal for applications where system excitation is required - such as audio and electroacoustic test applications.
 

Type 3160 comes in two basic variants, offering the choice between 2 inputs/2 outputs (this product) and 4 inputs/2 outputs. All input and output channels have a frequency range of DC to 51.2 kHz.

 

Type 3160 works equally well as a single-module test system, or as one part of a large LAN-XI measurement system. The combination of inputs and output channels makes it one of the most versatile data acquisition modules available, while interchangeable front-panels give the flexibility to use a wide range of transducers.

USE SCENARIOS

  • General sound and vibration measurements
  • Generator output channels for system excitation for sound and vibration measurements
  • Ideal for audio and electro-acoustic measurements
  • Measurement front-end module for PULSE measurement and analysis software
  • Front-end for PC-based data recorder Type 7708
  • Single-module measurements
  • Multi-module measurements/ distributed system
  • Stand-alone recording (no PC) using LAN-XI Notar™ software
  • Wireless frontend for Sonoscout

File

Description

Type

Languages

Size

LAN-XI Data Acquisition Hardware

Technical Document English 5 MB
Key attributes: DAQ Systems
Number of inputs 2
Input Standardized voltage (+/- 10V), IEPE / CCLD, 200V condensor microphones
Output Voltage (+/- 10V)
Interface TCP/IP
Accuracy class n/a
Degree of protection IP31
Sample rate [S/s] 131 kHz
Housing Frame
Real-time capabilities None