arrow_back_ios

Main Menu

See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Test Solutions See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Articles See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

1-GN611B

GHS CARD, 6CH HighVoltage, 200kS/s

High Voltage input card, 6 channels; 200 kS/s, 18 bit, 200 MB RAM.
*** features ***
- isolated
- ±10 mV to ±1000 V input range
- 1 kV isolated balanced differential input
- 600 V RMS CAT II isolation reinforced
- 4 mm fully isolated banana plugs
- analog/digital anti-alias filters
- 16 digital events and two counter / timer inputs
*** compatibility ***
tethered mainframes: GEN2tB, -3t, -4tB, -7tA, -17tA
mainframes with integrated PC: GEN3i, -3iA, -7i,
-7iA
***options (factory installed, order seperately)***
- real-time formula data base 1-GEN-OP-RT-FDB

img

GHS CARD, 6CH HighVoltage, 200kS/s

expand_more
chevron_left
chevron_right

Input Card for High Voltage ISO: 1000V - GN611B

Tested up to 6.4 kV, the reinforced isolation allows for safe measurements up to 600 V RMS CAT II (IEC61010-1:2010 safety standard). The six isolated balanced differential inputs offer voltage ranges from ± 10 mV to ± 1000 V 

  • GN611B: 18 bit resolution, 200 kS/s

Besides the instantaneous values, the realtime cycle detection allows for cycle-based real-time calculations like TrueRMS on all analog channels as well as torque, angle and speed on all timer counter channels simultaneously.
The real-time formula database calculators option offers an extensive set of math routines to solve almost any real-time mathematical challenge like obtaining mechanical power and/or multi-phase (not limited to three) electric power (P, Q, S) or even efficiency calculations.

Safe

  • 1 kV RMS CAT IV probe

  • 5 kV RMS certified probe

Fast

  • Sample rates from 0.1 S/s to 200 kS/S or 2 MS/s per channel
  • 18 bit resolution
  • User-selectable analog/digital filters

Real-Time

  • Real time formula database

  • Real-time cycle based calculators

  • Triggering on real-time results

File

Description

Type

Languages

Size

GEN Series GN611B - Data Sheet (B04375)

GEN Series GN611B - Data Sheet

Technical Document English 8 MB
KAB2148 - Data Sheet (B05756)

KAB2148 - Data Sheet

Technical Document English 2 MB
KAB2139 - Data Sheet (B05612)

KAB2139 - Data Sheet

Technical Document English 997 KB
Genesis High Speed - Brochure (US) (S04053)

Genesis High Speed - Brochure (US)

Marketing Document English 4 MB
Key attributes: DAQ Systems
Number of inputs 6
Input Electrical voltage, Electrical current, Digital encoder, Digital static input
Output Static digital I/O
Interface EtherNET I/P
Accuracy class 0.02
Degree of protection IP 20
Sample rate [S/s] 200 kHz
Housing Frame, Rack with PC
Real-time capabilities Calculation